4.10.4 Alarm Setup

In the main menu, from Setting->Event->Alarm, you can see alarm setup interface.
1. Alarm in: This is for you to select channel number. In the main menu, from
Setting->Event->Alarm, you can see alarm setup interface. See Figure 4-79. There are
four alarm types. See Figure 4-79 to Figure 4-82.
2. Local alarm: The alarm signal system detects from the alarm input port.
3. Network alarm: This is the alarm signal from the network.
4. IPC external alarm: This is the on-off alarm signal from the front-end device and can
activate the local HNVR.
5. IPC offline alarm: Once you select this item, system can generate an alarm when the
front-end IPC disconnects with the local HNVR. The alarm can activate record, PTZ, snap ,
etc.. The alarm can last until the IPC and the HNVR connection resumes.
Important
If this is your first time to booting up the device, the disconnection status of the
front-end network camera will not be regarded as offline. After one successful
connection, all the disconnection events will be regarded as an IPC offline event.
When an IPC offline alarm occurs, the record and snapshot function of digital channel
is null.
6. Enable: You need to highlight this button to enable current function.
7. Type: Normal open or normal close.
8. Period: Click set button, you can see an interface is shown in Figure 4-84. There are two
ways for you to set periods. There are max 6 periods in one day. There are four record
types: regular, motion detection (MD), Alarm, MD & alarm.
a. In Figure 4-84, Select icon
edited together. Now the icon is shown
from one period.
b. In Figure 4-84. Click button
interface shown in Figure 4-85. There are four record types: regular, motion
detection (MD), Alarm, MD & alarm.
9. PTZ activation: When an alarm occurred, system can activate the PTZ operation. The
PTZ activation lasts an anti-dither period. See Figure 4-83.
10. Anti-dither: Here you can set the anti-dither time. The value ranges from 5 to 600s. The
anti-dither time refers to the alarm signal lasts time. The alarm signal activation will
include the buzzer, tour, PTZ activation, snapshot, channel record. The stay time here
© Copyright Qvis ®. All documentation rights reserved.
to select the corresponding alarm output.
of several dates, all checked items can be
after one date or a holiday, you can see an
.
Click
to delete a record type
84