Qvis IZEUS 7000 NVR RANGE User Manual page 189

8 & 16 channel network video recorders
Table of Contents

Advertisement

Please refer to the following sheet for detailed information:
Parameter
Function
Enable
You need to check the box to enable motion detection function.
Please select a channel from the dropdown list.
Period
System only memorises one event during the anti-dither period.
Anti-dither
The value ranges from 5s to 600s.
There are six levels. The sixth level has the highest sensitivity.
Sensitivity
Region
If you select motion detection type, you can click this button to set
motion detection zone. The interface is shown as in Figure 5-51.
Here you can set motion detection zone. There are four zones for
you to set. Please select a zone first and then left drag the mouse
to select a zone. The corresponding color zone displays different
detection zone. You can click Fn button to switch between the arm
mode and disarm mode. In arm mode, you can click the direction
buttons to move the green rectangle to set the motion detection
zone. After you completed the setup, please click ENTER button to
exit current setup. Do remember click save button to save current
setup. If you click ESC button to exit the region setup interface
system will not save your zone setup.
Record
System auto activates motion detection channel(s) to record once
channel
an alarm occurs. Please note you need to set motion detect record
period and go to Storage-> Schedule to set current channel as
schedule record.
Record Delay
System can delay the record for specified time after alarm ended.
The value ranges from 10s to 300s.
Alarm out
Enable alarm activation function. You need to select alarm output
port so that system can activate corresponding alarm device when
an alarm occurs.
Latch
System can delay the alarm output for specified time after an
alarm ended. The value ranges from 1s to 300s.
Show
System can pop up a message to alarm you in the local host
message
screen if you enabled this function.
Buzzer
Check the box here to enable this function. The buzzer beeps
when an alarm occurs.
Alarm upload
System can upload the alarm signal to the centre (Including alarm
centre.
Message
When 3G network connection is OK, system can send out a
message when motion detect occurs.
Send Email
If you enabled this function, System can send out an email to alert
you when an alarm occurs.
© Copyright Qvis ®. All documentation rights reserved.
Motion detection function becomes activated in the specified
periods. See Figure 5-50.
There are six periods in one day. Please draw a circle to
enable corresponding period.
Click OK button, system goes back to motion detection
interface; please click save button to exit.