(5) Disconnect 1 connector, release the latches
and take off the intermediate transport sensor.
(G-9) RADF open/close switch
(1) Remove the ADF rear cover.
(2) Disconnect 3 connectors.
(3) Remove 1 screw and take off the RADF open/
close switch with the bracket.
(4) Remove 1 screw and release the RADF open/
close switch from the bracket.
<Installing procedure>
(5) After installing the RADF open/close switch to
the bracket, connect the connectors to it in
the alignment shown by the right figure.
(G-10) Large original exit sensor
(1) Open the jam access cover.
(2) Open the reverse guide and unjoint the front
side inlet and take off the guide toward the
front side.
(3) Open the scanning guide, unjoint the inlets at
both sides and take off the guide upward while
holding both sides.
(4) Remove 2 screws and take off the large
original exit guide.
JUNE 2002 © TOSHIBA TEC
RADF open/close switch
16 - 83
Intermediate transport sensor
Blue Orange Brown
Scanning guide
Large original exit guide
e-STUDIO550/650/810 RADF