[B] Fuser unit
(1) Remove 2 screws and open the cover forward
slowly.
(2) Remove 4 screws and release the IH coil fuser
harness. Disconnect 2 connectors.
(3) Remove 1 screw and open the cover 2 forward.
(4) Remove 1 screw move the fuser unit forward
and lift it off upward.
Notes: 1. Make sure that the harness (A) at the right
figure does not touch the bearing and shaft
of the transfert/transport unit when installing
the fuser unit.
2. Remove the fuser unit after fully lowering
the temperature or wear gloves and such
when removing it at a high temperature.
3. Hold B sections of the fuser unit when
installing/removing it.
[C] Cleaning web unit
(1) Remove 2 black screws and take off the cleaning
web unit.
Note: The cleaning web unit can be taken off without
removing the fuser unit.
(2) Remove 4 E-rings and take off the cleaning web.
(3) Remove 2 E-rings and take off the bushing and
gear.
Caution:Be carefull not to slack off the cleaning web
when installing it.
e-STUDIO550/650/810 FUSER UNIT
Cover 2
B
E-ring
E-ring
14 - 14
C
S
C
S
G
Connector
A
Cleaning web
E-ring
JUNE 2002 © TOSHIBA TEC