[F] Solenoids
(F-1) Small original exit solenoid
(1) Remove the ADF rear cover.
(2) Remove the ADF board with the bracket.
(3) Remove the large original exit motor.
(4) Remove 1 screw and take off the small
original exit solenoid with the bracket.
(5) Remove 2 screws and release the small
original exit solenoid from the bracket.
(F-2) Large original exit solenoid
(1) Remove the ADF front cover while keeping
the jam access cover open.
(2) Disconnect 1 connector.
(3) Remove 1 screw and take off the large
original exit solenoid with the bracket.
(4) Remove 1 screw and release the large
original exit solenoid from the bracket.
(F-3) Disengagement solenoid
(1) Remove the ADF front cover.
(2) Remove the clip and take off the disengage-
ment solenoid link.
(3) Remove 1 screw fixing the harness duct,
release 2 latches and move the harness duct
to the right side.
(4) Remove 1 screw fixing the disengagement
solenoid bracket, disconnect 1 connector and
take off the disengagement solenoid with the
bracket.
(5) Remove 2 screws and release the disengage-
ment solenoid from the bracket.
JUNE 2002 © TOSHIBA TEC
Small original exit solenoid
Large original
exit solenoid
(F-2)(3)
Disengagement solenoid
16 - 79
Connector
Estrangement
solenoid link
Harness
(F-3)(3)
(F-3)(4)
e-STUDIO550/650/810 RADF
duct

Hide quick links: