en | Settings
Keypad Medical Aid Reporting
If you press and hold both 7 and 9 for 3 seconds, the medical aid alarm report will be sent.
The medical aid alarm report has no corresponding alarm recovery report.
Automatic Test Reporting
The system supports sending automatic test report.
For more information about test report time programming, see Test Report Time. For more
information about date and time settings, see Date and Time Settings.
Report Expiry Time
If the report expiry time expires and the report path has not been connected to, the report will
be lost and not be sent. It can be maintained for 1 to 255 minutes. The system is defaulted to
000, indicating that the report has been tried to send without limit in expiry time.
Report Delay Entry Time
When the alarm occurs during entry time, then the AMAX panel sends report immediately or
delayed (30 sec.).
7.1.3

Automatic Test Report

The test report is divided into two types: periodic and regular daily report.
7.1.4

Dual IP

Dual IP Settings are valid only when used with Conettix IP communication format. IP module 1
is ITS-DX4020-G module or B426 module; IP module 2 is B426 module. IP module 2 does not
support RPC connection.
When the report is transmitted with Conettix IP Communication, some reports might be
missed. It is recommended not to separately use the ITS-DX4020-G module. If the ITS-DX4020-
G module is used, other network modules (e.g. B426) or the public telephone network can be
set as backup channel to ensure that no reports are missed.
The communication path of B426 / ITS-DX4020-G is as follows:
Module
Module 1: B426 module 1 / ITS-
DX4020-G
Module 2: B426 module 2
Only when IP module 1 is used and set to paths 1 to 4, the report can be sent to those paths.
7.1.5

Remote Access

The AMAX panel supports remote programming via USB, telephone or IP network using
software A -Link Plus.
2014.4 | 01 | F.01U.267.112
When the addresses 0129 - 0130 are programmed in 1 - 99, the system will send periodic
automatic test report at every hour specified by the address. If 0129 - 0130 are
programmed to 0, no periodic test reports will be sent.
When 0131 - 0134 is set to valid time, the system will send automatic test report at the
same time every day. At this moment, the date and time of the system must be correctly
set. If 0131 - 0134 is set to be invalid time, the daily regular automatic test report will be
disabled.
uploading / downloading programming parameters
Address Setting
134
250
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Corresponding
Communication Path
Paths 1 and 2
Paths 3 and 4
Bosch Sicherheitssysteme GmbH
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icp-amax4-p2-enIcp-amax-p3-enAmax 4000Amax 4000en

Table of Contents