08 - Key Switch Toggle
The key switch toggle zone will perform as below:
1.
2.
3.
This zone will ignore all other programming items, such as bypass, forcing arm.
When the system is armed in this mode, the keypad activates two beeps and report sent is by
User Code 254.
09 - Key switch On / Off
The Key Switch on / off zone will perform as below:
1.
2.
3.
Wiring Diagram for key-switch Zone: short for arm. The momentary time is capable of lasting
Minimum 300ms.
Wiring Diagram for key-switch Zone: open for arm. The momentary time is capable of lasting
Minimum 300ms.
2014.4 | 01 | F.01U.267.112
AWAY Arm:
–
Zone normal - no alarm / no report
–
Zone triggered - alarm / report
–
Zone triggered - during exit time - alarm / report
–
Zone triggered - during entry time - alarm / report
STAY Arm: same as AWAY arm performance.
–
A 24 - hour zone does not send a restore report until the zone is restored
Disarm:
–
Zone normal - no action
–
Zone triggered - activate AWAY arm / report
AWAY Arm:
–
Zone normal - no action
–
Zone triggered - activate disarm / report
STAY Arm:
–
Zone normal - no action
–
Zone triggered - activate disarm / report
Disarm:
–
Zone normal - no action
–
Zone triggered - activate AWAY arm / report
AWAY Arm:
Zone normal - activate disarm / report
Zone triggered - no action
STAY Arm:
–
Zone normal - activate disarm/ report
–
Zone triggered - activate AWAY arm/ report
COM
Zone
COM
Zone