Bosch ICP-AMAX4-P1 Installation Manual page 50

Amax panel 4000; amax panel 4000 en
Hide thumbs Also See for ICP-AMAX4-P1:
Table of Contents

Advertisement

50
en | Settings
2.
3.
08 - Key Switch Toggle
The key switch toggle zone will perform as below:
1.
2.
3.
This zone will ignore all other programming items, such as bypass, forcing arm.
When the system is armed in this mode, the keypad activates two beeps and report sent is by
User Code 254.
09 - Key switch On / Off
The Key Switch on / off zone will perform as below:
1.
2.
3.
Wiring Diagram for key-switch Zone: short for arm. The momentary time is capable of lasting
Minimum 300ms.
Wiring Diagram for key-switch Zone: open for arm. The momentary time is capable of lasting
Minimum 300ms.
2014.4 | 01 | F.01U.267.112
AWAY Arm:
Zone normal - no alarm / no report
Zone triggered - alarm / report
Zone triggered - during exit time - alarm / report
Zone triggered - during entry time - alarm / report
STAY Arm: same as AWAY arm performance.
A 24 - hour zone does not send a restore report until the zone is restored
Disarm:
Zone normal - no action
Zone triggered - activate AWAY arm / report
AWAY Arm:
Zone normal - no action
Zone triggered - activate disarm / report
STAY Arm:
Zone normal - no action
Zone triggered - activate disarm / report
Disarm:
Zone normal - no action
Zone triggered - activate AWAY arm / report
AWAY Arm:
Zone normal - activate disarm / report
Zone triggered - no action
STAY Arm:
Zone normal - activate disarm/ report
Zone triggered - activate AWAY arm/ report
COM
Zone
COM
Zone
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Bosch Sicherheitssysteme GmbH
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icp-amax4-p2-enIcp-amax-p3-enAmax 4000Amax 4000en

Table of Contents