AMAX panel 4000 / AMAX panel 4000
EN
Remote PC Setting
Address 0162 - 0179
RPC IP no
RPC port number
AMAX panel DHCP update time (hours)
RPC is a remote programming computer equipped with remote programming software.
Remote Access To Panel When Panel Is Armed
Address 0180
0 = disable, 1 = enable ; default 1
Keypad Language
Address 0181
0 = default, 1 = EN, 2 = DE, 3 = ES, 4 = FR, 5 = IT, 6 = PL, 7
= NL, 8 = SE
Tamper Reset For User
Address 0182
0 = disable, 1 = enable
Arm / Disarm For Installer
Address 0183
0 = disable, 1 = enable
Zone Tamper Bypass when DEOL Zone is Bypassed
Address 0184
0 = disable, 1 = enable
Onboard Tamper Reaction Time
Address 0185
0 = 400 ms, 1 = 150 ms
Bosch Sicherheitssysteme GmbH
This function is only accessible in address programming
This function is only accessible in address programming
Installation Guide
Address Programming | en
Address
Default
0162 - 0173
15
0174 - 0178
15
0179
15
Address
Default
0180
1
Address
Default
0181
0
Address
Default
0182
1
Address
Default
0183
0
Address
Default
0184
1
0=Incert
Address
Default
0185
0
1=Incert