Advertisement

AMAX panel 4000 / AMAX panel 4000
EN
Auxiliary Power Fault Report
When the system detects auxiliary power fault, the report will be sent.
Auxiliary Power Fault Restore Report
When the system detects auxiliary power fault recovery, the report will be sent.
AC Power Fault Report
When the system detects disconnection of AC power, the report will be sent.
AC Power Fault Recovery Report
When the system detects recovery of AC power, the report will be sent.
Battery Low Voltage Fault Report
When the battery voltage is lower than 11.0V or battery low voltage is detected in the dynamic
battery test, the AMAX panel will send the battery low voltage report.
The system continuously monitors the battery voltage and will perform a dynamic battery test
each time the system is armed, when the system is reset, or every 4 hours.
Battery Low Voltage Fault Recovery Report
When the battery voltage is lower than 12.0V or recovery to normal voltage is detected in the
dynamic battery test, the battery low voltage fault recovery report will be sent.
Times of Wrong Code Entry Exceeding Limit
When the times of entering wrong code reaches a specific value, an access denial report will
be generated and alarm will be made.
This function is used to prevent unwanted users from accessing the system. When the times of
entering wrong password reaches a specific value, the AMAX panel will execute following
actions:
On-board Output 1 – 2 Fault
When on-board output 1 or 2 fails, the report will be sent. When the on-board output resumes
to normal conditions, the programmable output fault recovery report will be sent.
Communication Path 1 - 4 Fault
When any communication path fails, the report will be sent. When communication resumes to
normal conditions, the communication fault recovery report will be sent.
Changing Programming Parameters
When the programming parameters are changed and take effect, the report will be sent.
Keypad Emergency Alarm Reporting
If you press and hold both 1 and 3 for 3 seconds, or press and hold both [#] and [*] for 3
seconds, the emergency alarm report will be sent.
The emergency alarm report has no corresponding alarm recovery report.
Keypad Fire Alarm Reporting
If you press and hold both 4 and 6 for 3 seconds, the fire alarm report will be sent.
The fire alarm report has no corresponding alarm recovery report.
Bosch Sicherheitssysteme GmbH
Zone Expansion Module Tamper: When tamper occurs in the zone expansion module, the
tamper report will be sent. After the tamper recovers, a tamper recovery report will be
sent
Keypad Tamper: When tamper occurs in any keypads, the tamper report will be sent.
After the tamper recovers, a tamper recovery report will be sent
Activate alarm siren and other alarm outputs
Lock all keypads for 3 minutes
Send an access denial report
Installation Guide
Settings | en
39
2014.4 | 01 | F.01U.267.112