RF Sensor Fault
Condition:
Any one wireless zone is abnormal (e.g., Remove the pyro from the smoke detector / ...) and
wireless module is enable.
Restore:
All wireless zone are normal and wireless module is enabled and fault is reset.
Supervise:
1.
2.
3.
1-8 RF Repeater 1-8 Missing
Condition:
No status report to receiver in the RF supervision interval and wireless module is enable.
Restore:
Have status report to receiver in the RF supervision interval and wireless module is enable and
fault is reset.
Supervise:
1.
2.
3.
Configuration Conflict Sensors
Condition:
Any one wireless zone configuration is error.
Restore:
All wireless zone configuration are correct and fault is reset.
Supervise:
1.
2.
Configuration Conflict Repeaters
Condition:
Any one repeater configuration is error.
Restore:
All repeater configuration are correct and fault is reset.
Supervise:
1.
2.
Configuration Conflict Keyfobs
Condition:
Any one keyfob configuration is error.
Restore:
Bosch Sicherheitssysteme GmbH
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
Report the wireless zone fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
RF Repeater Failure
Report the repeater missing fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
RF Config Failure
Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).
When the fault is reset, the FAULT indicator is turned off when there is no other system
fault.
Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).
When the fault is reset, the FAULT indicator is turned off when there is no other system
fault.