Page 1
ICP-CC408 Installation Guide ICP-CC408 Control Panel...
Page 2
Bosch. Except as specified above or where authorized by the Bosch Security Systems, Inc. reserves the right to Copyright Act 1968 (Cth), no part of this publication make changes to features and specifications of its products at any time without prior notification.
Arming or Disarming Both Areas at the 4.11 Isolating Zones ..........23 Same Time ............39 4.11.1 Standard Isolating..........23 Hold-Down Functions ........39 4.11.2 Code to Isolate ..........23 6.4.1 Arming the System in AWAY Mode... 39 Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 4
Telephone Line Fault Options.......52 15.19 System Status – Access Denied..... 67 15.20 System Status Reporting Options ....67 12.0 Dialer Options..........53 15.21 Test Reporting Time ........67 12.1 Dialer Options 1 ..........53 Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 5
19.4.1 Zone Allocations for Area 1......84 Figure 3: ICP-CP500PW Master Partitioned 19.4.2 Zone Allocations for Area 2......84 Codepad............ 18 19.5 User Code Allocations ........84 Figure 4: ICP-CP508W LED Codepad Showing Audible Alarm Buttons ......22 Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 6
Codepad Indicators When Changing Telco Arming/Disarming Sequence ..36 Table 38: Event Sequence........39 Table 39: Event Memory Playback ......39 Table 40: Alarm Link Panel Forms ......41 Table 41: Domestic Dialing Digits......44 Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
All system Quick Start parameters and options are detailed, but suitability is The following steps allow you to use the ICP-CC408 left to the individual. Each control panel can be Control Panel with factory default values. The default...
Repeat this procedure until you program all the required data. The factory default settings are selected for reporting to the monitoring station in Contact ID format. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Location 034, press [AWAY] to step to Location 035. armed, or at any time during siren run time. To move to the previous location: You can program the ICP-CC408 Control Panel Press [STAY]. using any of these two devices: For example, if you are positioned at Location 035, •...
[#]. stored in Location 000. 2. Connect the programming key to the PROGRAMMING KEY pins (next to the Auxiliary Module socket) at the top of the control panel printed circuit board. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Panel Memory to the Programming Key control panel’s printed circuit board. This command copies the control panel memory to the programming key. You can only use the CC891 Programming Key with the ICP-CC408 Control Panel. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Two beeps sound. Section 9.0 Domestic Dialing on page 43 for more information. Example (Auto Step Enabled) To enter the Primary Telephone Number 02 (pause) 9672 1055 when auto step is enabled: Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
You are positioned at Location 000 (the Primary If the Installer Code is unknown, you must return the Telephone Number for Receiver 1). control panel to your Bosch Distributor for exchange. 2. To program the number, press: A nominal fee applies for this service.
The default button is located at the top of the PCB next to the PROGRAMMING KEY socket. 3. Reconnect the AC MAINS supply to the control panel. 4. Wait 3 to 5 sec and release the default button. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
• Each time a new system fault is detected (the FAULT Section 4.5 on page 21 to arm the system in indicator flashes), the codepad beeps once per min. STAY Mode 2. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
The MAINS indicator shows when the operation. systems AC MAINS supply is normal or failed (refer to Table 11 on page 16). Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Refer to Table 13 on page 17. corresponding AREA ON/OFF indicator is lit in conjunction with the PARTIAL indicator. If the area is armed in AWAY Mode, only the ON/OFF indicator is lit. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
2. When two beeps sound, release the button. Press [AWAY] to stop the beeping and to The AWAY indicator lights and Exit Time starts. acknowledge the fault. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Forced Arming Arming the system when a zone is not sealed is known as forced arming. Refer to Section 14.3.7 Zone Options 2 on page 62 to enable forced arming for each zone. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
(refer to Section 6.1.4 on page 31) or a Master Code arming is not permitted. If this is the case, you must function (Section 6.2.6 on page 37). seal all zones or manually isolate them before you can arm the system. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Medical Alarm Report, program Locations 341 and 342 to 0 (refer to Section 15.11 Codepad Medical Report on page 66). A codepad Medical Alarm transmits a Contact ID Event Code 100 to a base station receiver. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
When the AC MAINS [STAY][STAY][1][STAY][3][STAY][4][STAY] supply is connected continuously for 2 min, the [AWAY] control panel sends an AC Loss Restore Report and the codepad automatically stops the once per min beep. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Receiver 1 or Receiver 2 are unsuccessful. the system is disarmed. The sensor watch fault clears after the registered zone is unsealed and resealed. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Receiver 1 or Receiver 2 are set up for base reporting, Receiver 1 and Receiver 2 can each The ICP-CC408 Control Panel can be remotely attempt up to twelve calls, per event, to the base operated using hand-held remote radio transmitters.
3. Press any of the [TRANSMIT] buttons on the hand-held transmitter to allow the control panel to learn transmitter’s ID code. Two beeps sound and the STAY and AWAY indicators are extinguished. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
If strobe indications are enabled, the strobe flashes for 6 sec to indications are enabled, the strobe flashes for 3 sec to indicate the system is armed. indicate the system is disarmed. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
2,11 Radio Control Output 1 2,12 Radio Control Output 2 2,13 Radio Control Output 1 – not armed in AWAY Mode 2,14 Radio Control Output 2 – not armed in AWAY Mode Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Enter the Installer Code and press [2][AWAY] If the repeat interval is set to 7 days, but you want [STAY][4][AWAY]. the first Test Report to be sent in 2 days, enter: [1 2 3 4 1][AWAY][2][AWAY] Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
9672 1777) when the system is armed in AWAY Mode, enter: [1 2 3 4 3][AWAY][1][AWAY][STAY] [1 6 1 9 6 7 2 1 7 7 7][STAY][2][AWAY] You can suspend the Telco arming sequence at any time. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Two beeps sound and the system returns to the disarmed state. Example If you want to automatically divert all incoming calls to another telephone number (for example, 9672 1777) when the system is armed in AWAY Mode, enter: Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
To enter Event Memory Recall Mode: Enter the Installer Code and press [8][AWAY]. Three beeps sound. The events are played back by the codepad indicators in reverse chronological order. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
To access a Master Code function: or delete a User Code. Enter the Master Code and press the corresponding function digit and the [AWAY] button. The Master Code functions are listed in Table 31. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
ICP-CC408 | Installation Guide | 6.0 System Functions EN | 34 When using a partitioned ICP-CC408 Control Panel, Table 32: User Numbers Displayed by the the Master Code holder cannot add, change, or Codepad Indicators delete User Codes unless the User Code is allocated to the same area as the Master Code.
These two beeps normally sound after you enter the last digit of the last phone number. 2. Enter the first phone number. Each digit appears as you enter it. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
These two beeps normally sound after the Pause last digit of the sequence is displayed. Break 3. Press [STAY][2 6 1][STAY][2][AWAY]. Two beeps sound and the system returns to the disarmed state. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
If no Telco disarming sequence is programmed, an additional two beeps sound after entering this mode. These two beeps normally sound after the last digit of the sequence is displayed. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Locations 414 to 417 (refer to Section order. 17.12 Auto Arming Time on page 77), or when you enter Fault Analysis Mode by holding down [5]. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Options 2 on page 83). system in STAY Mode 2. This hold-down function operates only if you select Option 2 in Location 429 (refer to Section 18.6 Consumer Options 2 on page 81). Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Day Alarm is active. individual tone using this function. To turn Day Alarm on: On partitioned ICP-CC408 Control Panels, this hold- Press and hold [4] until three beeps sound. down function also indicates the area to which the codepad belongs.
Send Test Report 8.0 Alarm Link Software Holding down [9] until two beeps sound transmits a You can program or control the ICP-CC408 Control Test Report (Contact ID Event Code 602) to test the Panel remotely using an IBM or compatible personal dialing and reporting capabilities of the system computer and the CC816 Alarm Link Software.
Remember that using this feature The direct connect feature gives the installer a simple reduces the security of the control panel. method to program the ICP-CC408 Control Panel using a portable computer. Because telephone lines Method One and modems are not required, programming the Method one allows you to call the control panel from control panel is easily completed in minutes.
2. Enter [9 6 5] and press [AWAY]. telephone number (if one is programmed) or Two beeps sound. The control panel is now set attempts the first telephone number again. up for Domestic Dialing Format. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Two beeps sound and the STAY and AWAY 10.1 Transmission Formats indicators are extinguished. The system returns The ICP-CC408 Control Panel provides a number of to the disarmed state. transmission formats for its dialing and 4. To program your telephone numbers, enter your communication features.
The third digit indicates the status of the AC MAINS supply. The fourth digit indicates whether a system fault occurred at the control panel (refer to Section 4.12 Fault Analysis Mode on page 23 for more information). Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Subscriber ID specific event information: (comprised of three (comprised of two (comprised of Number hex digits) hex digits) three hex digits) 1 – New event or opening 3 – New restore or closing Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Table 48: Dialing Digits 11.0 Dialer Information This section outlines the programming information Digit Number to Digit Number to required for the ICP-CC408 Control Panel when Required Program Required Program communicating with a base station receiver. These terminator parameters specify the telephone numbers to call, the transmission formats, handshake tones, and transmission speeds.
[0 0 4 7 2 9] 3 – 2300 Hz Reserved. 4 – No Handshake No Handshake Tone is not recommended. 5 – Pager Pager Handshake Tone is required to communicate in Basic Pager Format. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Callback Verification is required (refer to Section break 8.1.3 on page 42). Refer to Section 8.0 Alarm Link Software on page 41 To turn call forward (immediate) on, enter: for more information. [* 2 1][forwarding telephone number][#] Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
If you program 7 in this location, the horn speaker, bell, strobe, and EDMSAT outputs are all activated when the system is armed or disarmed. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
65) for this option to work. If you do not select this option, the communication For a partitioned ICP-CC408 Control Panel, an dialer does not operate. Open/Close Report is sent only for the area in which the alarm occurred.
13.2.1 ICP-CC408 User Codes Mode. The Installer Code can be up to four digits The ICP-CC408 Control Panel can have up to long. After the control panel is powered up, the sixteen programmable User Codes (1 to 16) to Installer Code can disarm the system if it is the first operate the system.
User Codes, the Standard Isolating method no longer operates. Only User Codes with a priority level of 4, 6, 12, or 14 can isolate zones using the Code to Isolate method. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
This Resetting operates when a zone programmed for Day feature allows you to install the ICP-CC408 Control Alarm is activated. The output is reset after the zone Panel at an existing site without changing the EOL is resealed.
Zone Pulse Count Report Code Zone Pulse Count Time Dialer Options Zone Options 1 You can program Zones 1 to 8 as any Zone Type. Zone Options 2 Report Code Dialer Options Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Keyswitch Zone. Refer to Section 13.3 User Code alarm. Priority on page 55 for more information. If a Delay-1 Zone is not restored when the system is disarmed, a Zone Restore Report is automatically sent to the receiving party. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Pulse Count Time options 8 to 15. Refer to Section 14.3.4 Zone Pulse Count Time on page 60 for more Option Description information. Lockout siren and lockout dialer Delay Alarm reporting Silent Alarm Sensor watch Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Mode 1, or STAY Mode 2 when using the latching 409 (refer to Section 17.7 Sensor Watch Time on page keyswitch input. Arming the system is not permitted 76). from the Keyswitch Zone. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
When isolating 24-Hour Zones, the system automatically sends a Zone Bypass Report when the zone is selected to be isolated. All non-24-Hour zones send a Bypass Report only when the system is armed. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Codepad Panic, Access Denied, and other When the Swinger Shutdown Count is reached, all system alarms do not affect the Swinger Shutdown zones that were activated are locked out according to Count. their individual lockout settings. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
4 + 2 Formats. It has no effect on Contact ID required, program Locations 329 and 330 Format because a Zone Bypass is always reported as as 0. Event Code 570. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
User Code when arming the system does reporting at all. not cause a Duress Alarm. For a partitioned ICP-CC408 Control Panel, this If you want a 3 to activate a Codepad Duress Alarm location is ignored if Option 1 is selected in Location instead of 9, select Option 2 in Location 430 (refer to 433 (refer to Section 19.3.2 Partitioning Options 2 on...
2 only when Receiver 1 fails, or there is no reporting MAINS supply is connected continuously for longer at all. than 2 min. If AC Fail Restore Reports are not required, program Locations 350 and 351 as 0. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
(refer to Section 18.2 System Options 2 on page 79). Hour of day (units digit) Minute of day (tens digit) Minute of day (units digit) Test Report (tens digit) Test Report (units digit) Repeat interval in days Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Time Base Multiplier Time Base Multiplier 16.0 Programmable Outputs Strobe Output (Default = Strobe – Reset in 8 hours) The ICP-CC408 Control Panel has four fully- Event Code programmable outputs on the main printed circuit Event Code board and one programmable output that operates Polarity the codepad buzzer.
All reset times reference Polarities 1 and This output operates after Exit Time expires when 8. Reset times vary depending on the the system is armed. The output is reset when the selected polarity. system is disarmed. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 70
Time on page 76 for setting the number of days Alarm Information on page 56 for programming zones before a zone registers as a faulty sensor watch zone. to operate for Day Alarm. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 71
EVENT TYPE = 2,7 output (Output 3) is set by default for strobe POLARITY = 10 operation and is programmed to reset automatically TIMEBASE = 2 after 8 hours. MULTIPLIER = 15 Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 72
ICP-CC408 Control Panels. receiver. The output is reset when the first Kiss-Off is received. This output does not operate for domestic formats. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Area 1 Codepad Data Terminal This output type is used to connect the data terminal of the Area 1 codepad when you are using the Master Partitioned codepad as the main codepad. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
The event occurs, it restarts the one-shot timer. The output switches back to open circuit when the one- output switches back to 0 V when the one-shot time shot time expires. expires. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Table 59. The multiplier value is a two-digit decimal number from 00 to 99. For greater accuracy, use 60 sec for 1-min intervals and 60 min for one-hour intervals. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Exit Time until the final 10 sec, when the codepad for Sensor Watch registers a Sensor Watch Fault if it sounds one continuous beep to indicate the end of is not activated while disarmed within 3 days. Exit Time is near. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Time, the Auto Arming Time programmed in This timer applies only to the 4 + 2 Express Format. Locations 414 to 417 (refer to Section 17.12 Auto Arming Time on page 77) is extended by 1 hour. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Refer to Minute of the day (units digit) Section 2.3 Programming Option Bits on page 11 for The ICP-CC408 Control Panel has a real-time more information. 24-hour clock you must set during installation. Set 18.1...
– AC Fail Report on page 66). dialer. If you want to disable the reporting of a Codepad Medical Alarm, program Locations 341 and 342 as 0 (refer to Section 15.11 Codepad Medical Report on page 66). Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
For partitioned ICP-CC408 Control MAINS frequency. If this option is not selected, the Panels, both areas are automatically control panel uses the MAINS frequency as a time armed. base to keep time. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
CP500PW Master Partitioned LED Codepad on page 18. programming a single value. Calculate this value by adding the option bit numbers together. Refer to Section 2.3 Programming Option Bits on page 11 for more information. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
If this option is selected, the DATA terminal on the Refer to Sections 6.2.1 and 6.3.1 on pages 33 and 39 ICP-CC408 Control Panel is configured to send only for more information. status information that is relevant to Area 1. This...
Locations 434 to 441: 1 2 3 4 0 0 0 0 Option Description Not allocated to an area Allocated to Area 1 Allocated to Area 2 Allocated to Area 1 and Area 2 Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Figure 16: DIP Switch Location on Codepad Codepads for Partitioning Only the CP5 Area Addressable (CP500AW) and CP5 Master Partitioned (CP500PW) Codepads can be used with a partitioned ICP-CC408 Control Panel. 19.6.1 Setting Up the Master Partitioned Codepad as the Main Codepad...
CP-5 Area Addressable (CP500AW) of accessories that can be used in conjunction with Codepads to function correctly. the ICP-CC408 Control Panel. These optional pieces 1. Set DIP Switch 1 on the back of the remote of equipment enhance certain features to make the codepad for Area 1 to the ON position.
20.6 CC816 Alarm Link Software This software package is designed to program the ICP-CC408 Control Panel by either the direct link or remote connect methods. This software can access all options and features and maintain history and service reports. Program options to use this feature in 1 –...
Option 8 in Location 427 (refer to Section 18.4 System Options 4 on page 80). 20.12 TF008 Plug Pack (TF008) The TF008 plug pack is used with ICP-CC408 Control Panels. The plug pack includes built-in thermal fuses that blow during overload or fault conditions to eliminate a possible fire threat due to excessive heat buildup inside the casing.
EOL resistor. The function of the zones and their response times are configured using the system programming options. If split EOL is programmed, 24-Hour Zones or Keyswitch Zones connected in parallel to Zones 1 and 2 act as Zones 5 and 6. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
A device used to arm and disarm a security system or to cause a panic alarm. remote control lockout dialer A dialer that activates only once per zone per arming cycle. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 91
A monitored input used to activate an alarm. A zone might be set up to activate an alarm only when the system is armed or to operate whether the system is armed or disarmed. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
22 – Battery 5 – Zone 2 14 – Smoke detector 23 – 18 VAC 1.3 A plug pack 6 – Zone 6 (TF008) 24 – Link between +12 V and Comm Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 93
IN – telecom line (street) 9 – Default switch 3 – Receiver interface connection 10 – Programming key 4 – Zone termination strip 11 – Auxiliary Module: direct link cable 5 – Output termination strip Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
The ICP-CC408 Control Panel allows you to save and the control panel. Anyone with some knowledge time and money by providing Test Reports only of alarm systems can trick the dialer that it is when the system is armed.
12-month period. as indicated by the date stamp or the serial number If you use the ICP-CC408 Control Panel, you can cut on the product. the calls to 624,000 per year (at a value of $156,000 Defective units returned by the purchaser at their assuming local calls), a saving of $65,000.
Reserved If the matter is reported to Telecom as a wiring Reserved fault and the fault is proven to be due to this Reserved product, a call-out charge will be incurred. Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 99
Locations 260 to 264 Open/Close Reports only after alarm 15 15 15 15 Default Open/Close Reports in STAY Mode allowed Delay siren until transmission complete Extend wait for handshake from 30 sec to 55 sec Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 100
Reserved Reserved Reserved Reserved 24-Hour Medical Split EOL (3K3/6K8) 1% resistors required. 24-Hour Panic Eight programmable zones. 24-Hour Holdup 24-Hour Tamper Reserved Keyswitch 24-Hour Burglary 24-Hour Fire Chime only Zone not used Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 101
Refer to page 65 7 15 Default Swinger Shutdown Count for Siren Codepad Fire Report Refer to page 63 Location Location 339 to 340 Refer to page 66 Default 7 14 Default Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 102
Increments of 16 sec (0 to 240 sec) Location 363 Minute of the day – units digit Location 364 Test Report code – tens digit Location 365 Test Report code – units digit Location 366 Repeat interval in days Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 103
Bosch Security Systems, Inc. smart lockout allowed Refer to page 81 Location Horn speaker monitor Default Strobe indications for radio arm/disarm WE800/E Radio Receiver Allow horn speaker beeps for radio arm/disarm Latching keyswitch input Momentary keyswitch input Reserved Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 104
Day of the month – units digit Location 907 Month of the year – tens digit Location 908 Month of the year – units digit Location 909 Year – tens digit Location 910 Year – units digit Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
ICP-CC408 | Installation Guide | 25.0 Country Codes EN | 105 25.0 Country Codes The PSTN provides a programmable line interface to meet international telephone line requirements. This program meets various country PTT standards. Country Code Country Code Country Code...
Page 106
ICP-CC408 | Installation Guide | 25.0 Country Codes EN | 106 Country Code Country Code Country Code Country Code Country Code New Zealand Bahrain El Salvador Nepal Nigeria French Equatorial Gui Nicaragua Polynesia Norway Iceland Eritrea Niger Peru Israel Ethiopia...
Page 107
Disarming ..............20 Call Back Telephone Number......51 Bell Test ..............40 Dialling Format.............51 Bypass Reports ............64 Call Back Telephone Number........51 Primary Telephone Number For Receiver 1 ...49 Changing User Codes..........37 Programming Telephone Numbers ....49 Codepad Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 108
Armed In AWAY Mode ........69 966 - Automatic Stepping Of Locations ....13 Armed In STAY Mode ........69 999 - Display Panel Type/Software Version Number ..............14 Auto Arm Pre-Alert Time ........69 Introduction ..............8 AUX Power Supply Fail........70 Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 109
Operating Outputs ..........28 Ring Detect............72 Remote Radio User Codes Sensor Watch Alarm..........70 Adding Or Changing ........26, 34 Silent Alarm ............71 Deleting............26, 35 Sirens Running............71 Reporting Format Strobe Operating ..........71 Domestic Dialling..........43 Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 110
Chime Zone ............60 Telephone Anti-Jamming........96 Delay-1 Zone............59 Telephone Monitor Mode ........32 Test Reports ..............41 Delay-2 Zone............59 Only When Armed ........80, 96 Handover Zone.............59 TF008 Plug Pack............88 Instant Zone ............59 Trouble Reports ............64 Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Page 111
ICP-CC408 | Installation Guide | Index EN | 111 Notes Bosch Security Systems, Inc. | 12/08 | F01U089463-02...
Need help?
Do you have a question about the ICP-CC408 and is the answer not in the manual?
Questions and answers