Forced Arming
If this option is selected, the system can be armed when the zone is in triggering status. If this
option is not selected, the system will not allow the PIN holder to arm the system unless the
zone with problems has resumed to normal status or been manually bypassed.
The arming with a zone in triggering status is called forced arming.
When the operating system arms:
The exceptions to forced arming option:
Silent Alarm
Enabling this option can set the zone to mute alarm. Silent alarm will not trigger the output of
keypad buzzer and the output of the type of event of system audio alarm, but can trigger the
output of the type of event of system alarm (both sound and silent) and the alarm event can
still be transmitted according to programming path.
Zone Locking
The zone locking option of each zone can be set to a non-locking 1 time locking, 3 time
locking, 6 times locking and follow alarm time.
For unlocking, set the zone locking option to 0 to disable the zone locking function.
3 times of alarm locking
If the locking option is set to 2, the zone can only transmit up to 3 times of alarm report in
each arming period. After zone re-disarming re-arming, the locking count will be reset.
The AMAX panel will process locking according to the following logic:
1.
2.
3.
4.
5.
6 times of alarm locking
Similar to 3 times of alarm locking, with alarm limited to not more than 6 times.
Locking within the period of alarm output time. Repeating the process of alarm locking in the
period of alarm output time, without limit to times.
Zone Tamper
The system supports the tamper detection of the zone. This function ensures that the zone is
in normal operating status. The process is as follows:
1.
Bosch Sicherheitssysteme GmbH
When the keypad or key switch zone is used to execute system arming, the system will
show the zone status at first. If a zone in triggering status is not bypassed and the forced
arming option is in disabled status, it cannot be successfully armed.
When the keypad or key switch zone is used to execute system arming, the system will
show the zone status at first. If a zone in triggering status is not bypassed and the forced
arming option is in enabled status, the system will be successfully armed. If the zone is
still not recovered at the end of the exit delay time, the system will show the fault report
of the zone.
When the fault is recovered, a zone recovery report will be sent.
In telephone and programming software remote arming, forced arming is available no
matter the zone is programmed as enabled or disabled forced arming.
When the zone or zone tamper is trigger and siren alarm is resulted, within the period of
alarm output time, the AMAX panel will ignore the status detection of the zone.
When the alarms rings 3 times, the zone will be locked.
If the alarm occurs in the locked zone, the zone will send zone fault report.
Before the end of the alarm output time, ten zone recovery event will not be transmitted.
If the zone locking option is disabled, the times of alarms will not be restrained. Even
when other zones are locked, that zone can still generate the alarm.
If 24-hour zone tamper is enabled, the wiring method for two-terminal resistor is
required.
Installation Guide
Settings | en
57