52
en | Settings
2.
3.
15 - External Fault
The fault zone / input will perform as below:
1.
2.
3.
16 - Delay Exit
The delay exit zone will perform as below:
1.
2.
3.
17 - Interior Delay Exit
The Interior delay exit zone will perform as below:
1.
2.
3.
2014.4 | 01 | F.01U.267.112
–
Zone normal - no alarm / no report
–
Zone triggered - no alarm / no report
AWAY Arm:
–
Zone normal - no alarm / no report
–
Zone triggered - no alarm / no report
–
Zone triggered - during exit time - no alarm / no report
–
Zone triggered - during entry time - no alarm / no report
STAY Arm: same as AWAY Arm performance.
–
This zone is mainly for prevention of arming (to ensure exit/entry door is locked
before arming the system and no alarm occurs when entering the premise through
the entry/exit door)
Disarm:
–
Zone normal - no alarm / no report
–
Zone triggered - fault / report
AWAY Arm:
–
Zone normal - no alarm / no report
–
Zone triggered - alarm / report
–
Zone triggered - during exit time - fault / report
–
Zone triggered - during entry time - fault / report
STAY Arm: same as AWAY Arm performance
–
The restore report will be sent when the zone is restored
DISARM: same as Instant zone disarm status
AWAY Arm:
–
Zone normal - no alarm / no report
–
Zone triggered - entry time starts - no alarm / no report
–
Disarming during entry time - no alarm / no report
–
Zone triggered - during exit time - no alarm / no report / abbreviates remaining time
for exit to 5 s
–
Zone triggered - during entry time - no alarm / no report
–
Zone triggered - entry time is expired - alarm / report (report is delayed for 30
second, when system is disarmed before, no report)
STAY ARM: same as AWAY ARM performance
–
First delay zone will start the entry time; all other delay zones will follow
–
When system is disarmed and zone is not restored before, a zone restore report is
sent
Disarm: same as the Instant zone disarm status
AWAY Arm: same as the delay exit zone AWAY arm status
STAY Arm:
–
This zone will be Ignored and performed as disarm
–
Refer to Keypad Indicators to see how the zone is displayed during exit time