Output Settings; Siren Settings - Bosch ICP-AMAX4-P1 Installation Manual

Amax panel 4000; amax panel 4000 en
Hide thumbs Also See for ICP-AMAX4-P1:
Table of Contents

Advertisement

82
en | Configuration
6 OUTPUT MANAGER
Figure 8.6: Output setting
2014.4 | 01 | F.01U.267.112

OUTPUT SETTINGS

ENTER OUTPUT No.
OUTPUT EVENT TYPE
OUTPUT AREA / ZONE
OUTPUT MODE
OUTPUT TIME: sec

SIREN SETTINGS

SIREN TIME: min
SIREN BEEP ENABLE
INT SIREN INDIC ON
SIREN OFF ANY KEY
1 - 20
00 = not used
01 = system Disarmed *¹
02 = system Armed *¹
03 = system Alarm
04 = sys Alarm audib + Silent
05 = ext. AWAY siren
06 = ext. STAY Siren
07 = int. siren
08 = int. siren w. tamper
09 = entry/exit delay *²
10 = tel. line fault
00 = any Area 01 – 16 Area 1 - 16
00 = continuous
000 - 999 seconds
00 - 99 = 0 - 99 minutes Master Timer for Outputs
0 = disabled 1 = enabled
0 = disabled 1 = enabled
0 = disabled 1 = enabled
Installation Guide
AMAX panel 4000 / AMAX panel 4000
11 = ext. AWAY siren
21 = follow zone event *³
12 = battery fault
22 = RF keyfob door button
13 = tamper
23 = RF keyfob light button
14 = ext. fault
24 = chime indication
15 = all faults
25 = verified alarm
16 = fire alarm
26 = unverified alarm
17 = fire reset
27 = technical alarm
18 = AWAY armed *¹
28 = bypassed zone
19 = STAY armed *¹
29 = ready to arm *¹
20 = reset
30 = walktest
*¹ 00 = all Areas
*³ 01–64 Zone 1-64
01–16 Area 1-16
*² 01–16 Area 1-16
01 = Pulse
02 = continuous inverted
Bosch Sicherheitssysteme GmbH
EN
default
Output
No
1=[5]
2=[5]
3=[5]
4=[7]
5=[0]
....
[00]
[000]
[00]
[1]
[1]
[1]