Single-Button arm / disarm
Keyswitch arm / disarm
7.2.5

Code Permissions

Tamper Reset by User
The AMAX panel may allow tamper reset by user code. If this option is disabled, the installer
code only may perform tamper reset.
Arm / Disarm Installer
The AMAX panel may allow arm / disarm by using the installer code. If this option is disabled,
the installer code is not allowed to perform arm / disarm.
7.3

Zones

7.3.1

Add / Delete Zone

Based on zone numbers, when adding or changing each zone, it is required to specify the area,
select the zone functions and select the module of zone source.
When the zone is selected to 0, i.e., the zone is not used, any address set on the zone function
and module selection are invalid.
Zone Module
The AMAX panel supports onboard zones, keypad zones, AMAX 3000 / 4000, and DX2010
zones and RF zones.
Zone Function / Type
Zone Function Option
Zone Type
Bosch Sicherheitssysteme GmbH
Description
00
Zone not used
01
Instant
02
Interior instant
03
Delay
04
Interior delay
05
Follower
06
Interior follower
07
24-hour
08
Key-switch toggle
09
Key switch on / off
10
24-hour panic
11
24-hour fire
12
24-hour fire with verification*
13
Tamper
14
Bolt contact
15
External fault
Installation Guide
Report = 253
Report = 254
2014.4 | 01 | F.01U.267.112
Settings | en
47