DIP switches 5 and 6 are not used.
IUI-AMAX-LED8 and IUI-AMAX-LCD8 keypads can be set only to address 1 or address 2 through
the address jumper.
Address 1
Address 2
Table 5.3: Keypad Jumper Settings
5.2.3

Wiring

Connect the keypad to Bosch Option Bus of AMAX panel according to the following figure. The
last keypad must be placed within a cable distance of 200m.
AMAX 2100 / 3000
AMAX 4000
Figure 5.2: Connecting keypad to the AMAX Panel
Notice!
One single Bosch Option Bus is limited up to 8 keypads.
5.2.4

Status Indicator

If all indicators are blinking, then the keypad loses data connection to the AMAX panel.
5.3

DX2010

5.3.1

General

The AMAX panel supports DX2010 input expansion modules. Each expansion module supports
up to 8 zone inputs.
See also
Bosch Sicherheitssysteme GmbH
Jumper not short-circuited
Jumper short-circuited (both metal pins are covered)
Module Installation, page 23
Optional Modules and Peripheral Devices | en
Keypad
Installation Guide
13
2014.4 | 01 | F.01U.267.112