Bosch ICP-CC488 User Manual

Bosch ICP-CC488 User Manual

Control panel
Hide thumbs Also See for ICP-CC488:
Table of Contents

Advertisement

ICP-CC488
User's Guide
ICP-CC488
EN
Control Panel

Advertisement

Table of Contents
loading

Summary of Contents for Bosch ICP-CC488

  • Page 1 ICP-CC488 User’s Guide ICP-CC488 Control Panel...
  • Page 2 A-Tick with the supplier of the device to make the necessary repairs. The ICP-CC488 Control Panel is designed to comply Should the matter be reported to Telecom as a wiring with A-Tick. fault and the fault proven to be due to this product, a call-out charge will be incurred.
  • Page 3: Table Of Contents

    AWAY Indicator ........6 On/Off)............14 Table 4: STAY Indicator .........6 13.1 Telco Arm Sequence........14 Table 5: MAINS Indicator ........7 13.2 Telco Disarm Sequence .........14 Table 6: FAULT Indicator........7 Testing .............15 Table 7: Audible Indicators........7 Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 4 Table 12: Telco Arm/Disarm Dialing Digits ..15 Table 13: Domestic Dialing Telephone Digits ..17 Table 14: Zone Status Display Descriptions ..18 Table 15: System Status ...........18 Table 16: Glossary of Terms ........20 Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 5: Introduction

    2.5 kg (5.51 lb.) Supplier Code N771 New Zealand PTC 211/98/084 Telepermit ICP-CC488 – PTC 211/98/083 Test the sirens, strobe, and zones at weekly intervals. Refer to Section 14. Testing for further information. Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 6: Zone Indicators

    This indicator displays with the 1 sec off) indicator when the system is disarmed. MAINS Indicator The MAINS indicator displays that the system’s AC MAINS supply is normal or failed. Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 7: Off Indicator/Zone Sealed

    Table 8 defines the different methods for arming the Flashing There is a system fault that system. needs to be acknowledged. Audible Indications Table 7 defines the audible indicators given out by the codepad buzzer. Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 8: Forced Arming

    STAY Mode 2. automatically isolated. Only your security company can program zones automatically isolated in STAY Mode 1. Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 9: Programming Stay Mode 2 Zones

    2. Enter the radio remote user code number (9 to 16), followed by the [#] button (for example, [9#] = User 9, [16#] = User 16). Two beeps are heard and the selected user number displays on the codepad indicators. Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 10: Deleting User/Radio Codes

    2 – Disarm button 3 – Option 1 button 4 – Option 2 button 5 – Arm and Disarm buttons: Press both buttons at same time for 2 sec to send a Panic alarm Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 11: Codepad Alarms

    [7] and [9] simultaneously. Contact your isolated. installer to disable the codepad medical alarm Two beeps are heard and the system returns to function or to silence the codepad medical alarm. the disarmed state. Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 12: Code To Isolate

    ICP-CC488 | User's Guide | 9. Fault Analysis Mode EN | 12 Code to Isolate Fault Analysis Mode This method restricts only those User Codes with the Code to Isolate priority level to isolate zones. If a fault occurs, the FAULT or MAINS indicators If any User Code has this priority level, the flash and the codepad beeps once every min.
  • Page 13: Fault Descriptions

    DD = day of the month, MM = month of the year, YY = current year, HH = hour of the day, MM = minute of the day). To program the hour of the day, use the 24:00 hour format. Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 14: Turning Outputs On/Off

    4. Press the [#] key when finished. forward option available. Two beeps sound, and the STAY and AWAY indicators turn off. The examples given in this feature are only applicable to Australia. Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 15: 14. Testing

    [#] key to exit from this mode. Two beeps installed, each codepad can have a different tone. sound, and the STAY and AWAY indicators turn off. The system returns to the disarmed state. Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 16: Remote Arming By Telephone

    A group of four indicators display the following: 19. Partitioning AUX Indicator This feature only applies to the ICP-CC488 Control Displays when the control panel is using the Panels. Your control panel can be partitioned into telephone line communicating to the receiving party.
  • Page 17: Away Indicator 6

    If the call was successfully moving and do not want the system to continue acknowledged, a tone of decreasing pitch sounds. calling your mobile phone), enter the following sequence. Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 18: Basic Pager Reporting

    Section 8. Isolating Zones 11 for information on how to manually isolate a zone(s) prior to arming the system. Zone Trouble Indicates that a zone was left unsealed after the end of Exit Time. Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 19: Figure 9: Basic Pager Display

    1– Alarm 1 – AC Failure 2 – Manually Isolated 8 – 0 – System Normal 3 – Auto Isolated 1 – System Fault 5 – 8 – Disarmed 9 – Armed Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 20: 22. Glossary Of Terms

    A secure location where a digital receiver monitors a number of alarm systems and deciphers their alarm transmission reports so the operator can advise the appropriate authorities to take immediate action. Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 21 A monitored input used to activate an alarm. A zone might be set up to activate an alarm only when the system is armed or to operate whether the system is armed or disarmed. Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 22: Installation Notes

    ICP-CC488 | User's Guide | 23. Installation Notes EN | 22 23. Installation Notes Installation Company Technician’s Name Technician’s Telephone Number Installation Date Warranty Expiration Panel Software Version Service Notes Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 23 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Zone 16 Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 24 Single Button Disarming Remote Arming by Telephone Automatic Arming Time AM/PM Automatic Disarming Time AM/PM Output Descriptions Output 1 Output 3 Output 2 Output 4 Isolating Method Standard Isolating Code to Isolate Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 25 RF Device 13 ID Number RF Device 6 ID Number RF Device 14 ID Number RF Device 7 ID Number RF Device 15 ID Number RF Device 8 ID Number RF Device 16 ID Number Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 26 Domestic Dialling On Indicator Acknowledging Domestic Calls Output Disable Reset Latching Outputs Programming Domestic Telephone Numbers 18 Turning On/Off Duress Alarm Pager Reporting EEPROM Fault Panic Alarm 11, 21 Entry Delay/Entry Time Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 27 Silent Alarm Adding Specifications STAY Indicator Adding Radio Users STAY Mode 1 8, 22 Deleting Entry Guard Timer Walk Test STAY Mode 2 8, 22 Zone Indicators 6, 17 Entry Guard Timer Zones Bosch Security Systems, Inc. | 12/08 | F01U089456-02...
  • Page 28 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450-9199 USA www.boschsecurity.com © 2008 Bosch Security Systems, Inc. F01U089456-02...