en | Settings
Zone Bypass Report
After the manual bypass zone is operated, the zone will be bypassed. The zone bypass report
will be sent at the end of exit delay time.
The zone bypass will be recovered when the system is disarmed and the zone bypass recovery
report will also be sent while disarming.
Zone Tamper Alarm
In case of zone tamper event, the tamper report will be sent. When zone tamper recovers, the
system status report will be sent.
Arming / Disarming Reporting (System)
The system disarming report is sent at the disarming command and the system arming report
is sent when the arming succeeds.
Duress Report
The duress report is sent at the disarming command. The duress report will not be sent in the
operation of arming, but sent as ordinary arming report. The duress report has no
corresponding alarm recovery report.
Key Switch Arming
Sends system arming report when the transient key switch or locking key switch is used to
arm areas.
Quick Arming
Sends system arming report when the keypad is used for quick arming.
Telephone Arming
Sends system arming report when the telephone is used for arming of the panel.
Telephone arming is only available when there is Area 1 and 1 Area alternatively in the system.
RPC Arming
Sends system arming report when the remote PC is used to arm areas through network or
telephone connection.
Arming / Disarming Reporting (Perimeter)
The perimeter disarming report is sent at the disarming command and the perimeter arming
report is sent when the arming succeeds.
Quick Arming
Sends perimeter arming report when the keypad is used for quick arming.
RPC Arming
Sends perimeter arming report when the remote PC is used to arm areas through network or
telephone connection.
System Status Reporting
External Module Fault Report
2014.4 | 01 | F.01U.267.112
System tamper report: In case of case tamper event, the system tamper report will be
sent. When case tamper recovers, a tamper recovery report will be sent
Zone Expansion Module Fault: When zone expansion module 1 – 6 fails, the report will be
sent. After the fault is recovered, the recovery report will be sent
Output Expansion Module Fault: When output expansion module 1 or 2 fails, the report
will be sent. After the fault is recovered, the recovery report will be sent
Network Module Fault: When network module 1 or 2 fails, the report will be sent. After
the fault is recovered, the recovery report will be sent
Keypad Fault: When fault occurs between the keypad and the AMAX panel, the report will
be sent. After the fault is recovered, the recovery report will be sent