AMAX panel 4000 / AMAX panel 4000
EN
1.
2.
3.
04 - Interior Delay
The interior delay zone will perform as below:
1.
2.
3.
05 - Follower
The follower zone will perform as below:
1.
2.
3.
06 - Interior Follower
The interior follower zone will perform as below:
1.
2.
3.
07 - 24 Hour
The 24 - hour zone will perform as below:
1.
Bosch Sicherheitssysteme GmbH
DISARM: same as instant zone disarm status
AWAY Arm:
–
Zone normal - no alarm / no report
–
Zone triggered - entry time starts - no alarm / no report
–
Disarming during entry time - no alarm / no report
–
Zone triggered - during exit time - no alarm / no report
–
Zone triggered - during entry time - no alarm / no report
–
Zone triggered - entry time is expired - alarm / report
–
(report is delayed for 30 seconds, when system is disarmed before, no report)
STAY ARM: same as AWAY ARM performance.
–
First delay zone will start the entry time; all other delay zones will follow
–
When system is disarmed and zone is not restored before, a zone restore report is
sent
Disarm: same as the instant zone disarm status
AWAY Arm: same as the delay zone AWAY arm status
STAY Arm:
–
This Zone will be ignored and performed as disarm
–
Refer to Keypad Indicators to see how the zone is displayed during exit time
Disarm:
–
same as the instant zone disarm status
AWAY Arm:
–
Zone normal - no alarm / no report
–
Zone triggered – alarm / report
–
Zone triggered - during exit time - no alarm / no report
–
Zone triggered - during entry time - no alarm / no report
–
The remaining delay time is handed over from the delay zone to the follower zone.
–
The follower zone will performance as the same as a delay zone.
–
If there are two or more zones programmed as delay zones and both are triggered,
the follower zone will follow the first triggered delay zone
STAY ARM: same as the delay zone.
Disarm: same as the instant zone disarm status
AWAY Arm: same as the follower zone AWAY arm status
STAY Arm:
–
This zone will be ignored and performed as disarm
–
Refer to Keypad Indicators to see how the zone is displayed during exit time
Disarm:
–
Zone normal - no alarm / no report
–
Zone triggered - alarm / report
Installation Guide
Settings | en
49