Code to Isolate

1. Press [*].
2. Enter your user code and press [*].
3. Enter the zone number to isolate and press [*].
Repeat Step 3 to select other zones.
4. Press [#] to exit.
3.4

Set First Test Report

1. Enter the Installer Code and press [1 #] (for
example, [1 2 3 4 1 #]).
2. Enter the number of days (0 to 15) to wait until
the first Test Report, and press [#].
3.5

Event Memory Recall

Enter the Installer Code and press [8 #] keys (for
example, [1 2 3 4 8 #]).
The last 40 events appear in reverse order (most
recent to least recent).
3.6

Walk Test Mode

1. Enter the Installer Code or Master Code and
press [7 #] (for example, [1 2 3 4 7 #]).
2. Test each zone.
3. Press [#] to exit.
3.7

Satellite Siren Service Mode

Enter the Installer Code and press [5 #] (for
example, [1 2 3 4 5 #]).
3.8
Telephone Monitor Mode (Toggle
On/Off)
1. Enter the Installer Code and press [6 #] (for
example, [1 2 3 4 6 #]).
2. To send a Test Report, press and hold [9] until
two beeps sound.
The codepad indicators show the dialing events
(refer to Table 5 on page 6).
3. Enter the Installer Code and press [6 #] to turn
Telephone Monitor Mode off.
You must exit from Telephone Monitor
Mode to resume normal operations.
Table 5: Telephone Monitor Mode Zone LEDs
Zone LED
Dialing Event
1
Telephone line seized
2
Dialing telephone number
3
Handshake received
4
Data being sent
5
Kiss-off received
None
Released telephone line
6
Using the System
3.9

Add/Delete User Code/RF Keyfob

3.9.1

Add a User Code

1. Enter the Master Code and press [1 #] (for
example, [2 5 8 0 1 #]).
2. Enter the user number (1 to 16) to add, and press
[#].
3. Enter the new code and press [#].
3.9.2

Add an RF Keyfob

1. Enter the Master Code and press [1 #] (for
example, [2 5 8 0 1 #]).
2. Enter the user number (9 to 16) to add, and press
[#].
4. Press the RF keyfob until hearing two beeps. The
RF keyfob is added. Refer to the ICP-CC404
Installation Guide for more details.
You can only program User Codes 9 to
16 as RF users.
3.9.3

Delete a User Code/RF Keyfob

1. Enter the Master Code and press [1 #] (for
example, [2 5 8 0 1 #]).
2. Enter the user number (1 to 16) to delete, and
press [#].
3. Press [*] to delete the user code.
3.10
Change Domestic Telephone
Numbers
1. Enter the Installer Code or Master Code and
press [2 #] (for example, [1 2 3 4 2 #]).
2. Enter the digits of the telephone number.
3. If there is more than one telephone number,
enter [* 4] (which inserts a break between phone
numbers), then repeat Step 2.
4. Press [#] to exit.
3.11

Turn Outputs On/Off

1. Enter the Master Code and press [5 #] (for
example, [2 5 8 0 5 #]).
2. Enter the output number (1 to 3).
3. Press [#] to toggle the output on, or [*] to toggle
the output off.
4. Press [#] to exit.
3.12

Setting Date and Time

1. Enter the Master Code and press [6 #] (for
example, [2 5 8 0 6 #]).
2. Enter the day (DD), month (MM), year (YY),
hour (HH) and minute (MM).
3. Press [#] to exit.
3.13
Day Alarm – Toggle On/Off
Press and hold [4] until two beeps sound.
Day alarm toggles on or off.