14 - External Fault
This output operates when an external fault occurs.
The output is reset:
The output is reset when the output programmed duration is up.
lf this duration is programmed as 000, the output will continue till the external fault is
restored and the fault is reset.
15 - All Faults
This output operates when a fault occurs.
The output is reset:
When the output programmed duration is up.
lf this duration is programmed as 000, the output will continue till the fault is restored and the
fault is reset.
16 - Fire Alarm
The output is triggered when fire alarm.
17 - Fire Reset
The output is triggered when fire reset.
18 - AWAY Armed
This output operates when system is AWAY armed.
The output is reset:
1.
2.
19 - STAY Armed
This output operates when system is STAY armed.
The output is reset:
The output is reset when the output programmed duration is up.
lf this duration is programmed as 000, the output will continue till the system is disarmed.
20 - Reset
This output operates when a reset is performed in the system.
21 - Follow Zone Event Zone Number
The output follow type imitates the zone alarm state, when alarm or tamper is generated in
the corresponding zone, the output will be enabled. When system arming, disarming, or
output time ends, the output will be reset.
For actual output time, see Table The Value Ranges of Output Programming Options
22 - RF Keyfob button 3
The output is triggered when Keyfob Button 3 is pressed.
23 - RF Keyfob button 4
The output is triggered when Keyfob Button 4 is pressed.
24 - Chime Indication
Bosch Sicherheitssysteme GmbH
When the output programmed duration is up.
lf this duration is programmed as 000, the output will continue till the system is
disarmed.