AMAX panel 4000 / AMAX panel 4000
EN
RF Supervision Interval
Disables or defines RF Supervision Interval. The interval can be set to 1, 2, 4, 12, 24, or 25
hours.
RF Jam Detect Level
Defines RF jam detect level. The range is from 0 to 15 where 0 is most sensitive.
RF Device Low Level Battery Resound
Disables or sets the interval for keypad acoustic indication of RF device low level battery fault.
Siren Beep Arm / Disarm (RF Keyfob)
Enables or disables keypad acoustic indication on arm / disarm.
Keyfob Panic Option
Defines the behavior when keyfob panic button is pressed. The option can be set to no alarm,
silent alarm, or non silent alarm.
7.7.2

RF Devices / User

RF User
Keyfobs are designed for arming and disarming the system remotely, trigger a panic alarm, or
for additional control functionality.
To operate the buttons, simply press and hold either button for at least one sec in order to
use the desired feature.
The AMAX panel identifies Keyfob users by device RFID. AMAX Keypad programming supports
entering RFID automatically for radion devices. When Keyfob RFID is asked, press * button for
3s toggles between AUTO and MANUAL mode. When MANUAL is selected, enter 9 - Digit RFID
using pin keys. When AUTO is selected, trigger RF device in order to enter RFID automatically.
RF Repeater
The AMAX panel identifies repeater devices by device RFID. AMAX Keypad programming
supports entering RFID automatically for radion devices. When repeater RFID is asked, press *
button for 3s toggles between AUTO and MANUAL mode. When MANUAL is selected, enter 9-
Digit RFID using pin keys. When AUTO is selected, trigger RF device in order to enter RFID
automatically.
RF Sensor Diagnose
The AMAX panel supports diagnostic feature for RF sensors. Keypad diagnose displays signal /
noise ratio distance. In dependency of the rating, the AMAX panel provides an estimation of
GOOD or RELOCATE.
RF Repeater Diagnose
The AMAX panel supports diagnostic feature for RF repeaters. Keypad diagnose displays
signal / noise ratio distance. In dependency of the rating, AMAX panel provides an estimation
of GOOD or RELOCATE.
Clear RF devices
The AMAX panel provides the option to clear all RF devices in a step.