Address Setting; Wiring - Bosch ICP-AMAX4-P1 Installation Manual

Amax panel 4000; amax panel 4000 en
Hide thumbs Also See for ICP-AMAX4-P1:
Table of Contents

Advertisement

14
en | Optional Modules and Peripheral Devices
5.3.2

Address Setting

Each DX2010 module connected to the AMAX panel must have its own data bus address.
Data Bus Address
102***
103**
104**
105*
106*
107*
108*
Table 5.4: DX2010 Address Settings
DIP Switch
Data Bus Address
102***
103**
104**
105*
106*
107*
108*
Table 5.5: DX2010 DIP Switch Settings
* AMAX 4000
** AMAX 3000 / 4000
*** AMAX 3000
Example : Data Bus Location 103 - DIP Settings
Figure 5.3: DX2010 DIP Switch Settings
Notice!
When data bus address is changed, the module needs to be re-powered to make the new
address effective.
5.3.3

Wiring

Do not use twisted pair or shielded cables to connect DX2010 and the AMAX panel.
2014.4 | 01 | F.01U.267.112
S1
S2
32
16
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Zones
9 - 16
17 - 24
25 - 32
33 - 40
41 - 48
49 - 56
57 - 64
S3
S4
8
4
Off
Off
Off
Off
Off
Off
Off
On
Off
On
Off
On
Off
On