32
en | Settings
Contact ID Format
Contact ID Format can identify hundreds of zones by their unique codes. This format provides
a single-digit Event Qualifier and a three-digit Event Code that quickly identifies the reported
condition.
In general, Contact ID Format is very simple because most of the Event Codes and Point ID
Codes are predefined. The central monitoring station software usually can identify an alarmed
zone by its Point ID Code and usually pays little attention to the Event Code.
ACCT MT Q EEE GG CCC S
ACCT = Subscriber ID
MT = Message type, H
Q = Event Qualifier
1= New event or Opening
3= New restore or Closing
6= Previously reported off-normal event
EEE = Event Code
GG = Group Number (always 0)
CCC = Zone/ Contact ID, 000 is for no zone / ID message
S = Checksum digit
Note: Any 0 values must be sent as an 0x0A.
Contact ID Report Data.
SIA Format
AMAX panel supports SIA Format. SIA allows transmitting System ID, event code, zone ID, area
ID, event time, and also event text.
Conettix IP Format
AMAX panel supports Conettix IP. AMAX panel with DX4020G and B426 are able to connect to
Bosch Receivers 6600/6100 using Conettix IP Format.
Event Description
SYSTEM RESET
BURG ALARM
BURG ALARM RESTORE
BURG 24-HOUR
BURG 24-HOUR RESTORE
SENSOR FAULT
SENSOR FAULT RESTORE
SENSOR BYPASS
SENSOR BYPASS RESTORE
SENSOR TAMPER
SENSOR TAMPER RESTORE
ARM AWAY
DISARM AWAY
2014.4 | 01 | F.01U.267.112
Contact ID Message Format
CID
1130
3130
1133
3133
1380
3380
1570
3570
1144
3144
3401
1401
Installation Guide
AMAX panel 4000 / AMAX panel 4000
SIA
ALL
KP
Event
Recall
BA
BR
BA
BH
BT
BJ
BB
BU
TT
TJ
CL
OP
Bosch Sicherheitssysteme GmbH
EN
Dialer
EN
Event
Event

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icp-amax4-p2-enIcp-amax-p3-enAmax 4000Amax 4000en

Table of Contents