Access to the monitored area (doors not starting entry procedure) is prevented (e.g.
door strike, mechanically)
The Enclosure lock can only be used in non EN setup
Telephone arming can only be used in non EN setup
Accessory Modules, except input module (DX2010) can be used only inside the enclosure
(on the adapter plate)
When input module (DX2010) is used in the external enclosure (AE20), the tamper skirt
must be installed on the PCB of input module (DX2010)
The panel must be programmed with the EN settings indicated on the programming sheet
When the panel is set without EN parameters, the EN Indication (on Label) must be
removed
Maximum of 10 Devices shall be connected to one Zone Input (Panel, Keypad, Input
Module, RFUN,...)
Installation Guide
Installation | en
27
2014.4 | 01 | F.01U.267.112