AMAX panel 4000 / AMAX panel 4000
EN
Notice!
In case of common area, the area 1 will be the common area. When there is only 1 area in the
system, the address 0370 can only be programmed as 1.
Zone Area, Zone Functions, and Module Selection
Zone
no *
1
2
3
4
5
6
7
8
Notice!
Zones may be indicated on keypads with a number that are different from zone number used
for programming and hardware input.
Example:
Task:
In a area 1 system keypad, zone number 17 should be indicated as Zone number 16 (e.g.
visible on 16 zone LED keypad).
Procedure:
After disabling zone 16 * (or another one in range 1 to 16) zone number 17 is indicated on
keypad as number 16.
Notice!
When a zone is assigned to a RF device (3), then the dedicated on-board zone is not available.
* AMAX 4000 supports up to 64 zones, 16 keypads, and 16 areas
AMAX 3000 supports up to 32 zones, 8 keypads, and 8 areas
AMAX 2100 supports up to 8 zones, 4 keypads, and 2 areas
*** AMAX 3000 / 4000
Bosch Sicherheitssysteme GmbH
Area selection
Default
address
0678 - 0679
01
0680 - 0682
01
0682 - 0684
01
0684 - 0686
01
0686 - 0688
01
0688 - 0690
01
0690 - 0692
01
0692 - 0694
01
Value range: *
00 = zone not used,
1 - 16 = area 1- 16
Installation Guide
Zone function
Default
selection
address
0806
3
0807
1
0808
1
0809
1
0810
1
0811
1
0812
1
0813
1
Value range:0 –15. See
section Zone Functions
Address Programming | en
Module
Default
selection
address
0870
0
0871
0
0872
0
0873
0
0874
0
0875
0
0876
0
0877
0
0 = On-board zone
3 = RF device ***
15 = not used