Bosch ICP-AMAX4-P1 Installation Manual page 97

Amax panel 4000; amax panel 4000 en
Hide thumbs Also See for ICP-AMAX4-P1:
Table of Contents

Advertisement

AMAX panel 4000 / AMAX panel 4000
EN
System status report (zone fail, comm. fail, telephone line
fail, AC fail, low battery and so on.)
Keypad panic alarm report
Keypad fire alarm report
Keypad medical alarm report
Automatic test report
0 = no report, 1 = receiver 1, 2 = receiver 2, 3 = receiver 3, 4 = receiver 4, 5 = receiver 1,2,3,
and 4, 6 = receiver 1 (2,3, and 4 for backup), 7 = receiver 1 (2 for backup) and receiver 3 (4
for backup)
Notice!
When the transmission format for receiver in the receiver programming is set to 0 (not used),
i.e., setting the report option as sending report to a receiver, then the AMAX panel will
actually not send any report.
Automatic Test Report
Address 0129 - 0134
Test report time: interval
00 = Do not use timing report , 01 - 99 = 1 - 99 hours
Report time: hour
00 - 23 = 0 - 23 hours, others = do not use real-time report
Report time: minute
00 - 59 = 0 - 59 minutes, others = do not use real-time
report
Report Expiry Time
Address 0135 - 0137
000 = no time limit, 001 - 255 = 1 - 255 minutes
Installer Access Until Next Arming
Address 0138
0 = disabled, 1 = enabled
Force Arm When System Is In Trouble Condition
Address 0139
0 = disabled, 1 = enabled
Bosch Sicherheitssysteme GmbH
Installation Guide
Address Programming | en
0124
6
EN=1/5/6/7
0125
0
0126
0
0127
0
0128
6
EN=1/5/6/7
Address
Default
0129 - 0130
24
VDS-A
EN=1-24
0131 - 0132
99
0133 - 0134
99
Address
Default
0135 - 0137
000
VDS-A
EN=000
Address
Default
0138
0
VDS-A=1
Address
Default
139
1
VDS-A EN=0
2014.4 | 01 | F.01U.267.112
97