Settings; Communication And Reporting; Receivers - Bosch ICP-AMAX4-P1 Installation Manual

Amax panel 4000; amax panel 4000 en
Hide thumbs Also See for ICP-AMAX4-P1:
Table of Contents

Advertisement

30
en | Settings
7

Settings

This chapter specifies the properties and the behavior of the AMAX panel.
7.1

Communication and Reporting

This section outlines the programming information required for the AMAX panel when
communicating with a base station receiver. These parameters specify the telephone
numbers/IP address to be called, transmission formats, and internet communication options.
7.1.1

Receivers

Receiver Telephone number / IP Address and Port
The AMAX panel can report event information from four on-board dialers. The dialers report to
Receiver 1 to Receiver 4 by programming. You can program each dialer with 4 separate
telephone numbers/IP addresses and ports, reporting format type and subscriber ID number,
and internet communication options if necessary.
Example
You can set up Dialer 1 to report to receiver 1 in Bosch Network (Conettix) Format and set up
Dialer 2, Dialer 3, and Dialer 4 to report to a receiver of a central monitoring station in Contact
ID Format only, if Dialer 1 is unsuccessful.
To program a telephone number:
Each address in the telephone numbers stores one digit of the telephone number.
Insert a 15 at the end of a telephone number to indicate to the dialer that the end of the
telephone number is reached. The dialing sequence is terminated when a 15 appears.
Example
To program the telephone number 9672 1055 as the Telephone Number for Receiver 1,
program the following sequence into Address 000 - 016:
[9 6 7 2 1 0 5 5 15 x x x x x x x x] x stands for any digit. To enter a 4-sec pause in the dialing
sequence, program a 13. A pause might be necessary when the dialer communicates through
an old (slower) telephone exchange or when a PABX system is in place.
Example
To program the number 02 pause 9672 1055, enter:
[0 2 13 9 6 7 2 1 0 5 5 15 x x x x x].
The following table shows how to program the numbers, keys, and functions for a telephone
number.
Digit Required
0
1
2
3
4
5
6
7
Table 7.1: Dialing Digits
2014.4 | 01 | F.01U.267.112
Number to Program
0
1
2
3
4
5
6
7
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Digit Required
8
9
*
#
4 sec pause
Terminal
Bosch Sicherheitssysteme GmbH
EN
Number to Program
8
9
11
12