GROUND FAULT CIRCUIT OUTLET:
TEST
MONTHLY
it explains the system operation and shows the circuitry
throughout the vessel. The GFICI is normally located at the
beginning of a circuit so that all receptacles downstream are
protected. That could be a reason why several components
plugged into outlets will not work when a GFCI is not
functioning.
T h e G F C I ( G r o u n d
Fault Circuit Interrupter,
GFCI abbreviated) outlets
should be tested monthly.
To test the unit, depress
the reset button. Then
press the test button. The
reset button should pop
out. If it does not, contact
a qualifi ed electrician or
marine professional to
replace the device.
Note that all GFCI devices
are over time susceptible
to humidity and internal
contact corrosion.
Refer to Chapter 4 where
Note the following information is for reference only.
Notice the
Line
and
Load
the GFCI outlet. The wire labeled
supply current from the branch circuit breaker, and the wire
labeled
Load
will be the outgoing supply current from the
GFCI to all other outlets downstream.
There are 3 different wire colors connected to the GFCI
outlet for both the line and load cables. The connection
points of the GFCI labeled "HOT" are the current carrying
connections where the brown wires will connect. These
connectors must be connected correctly with respect to
the line and load side of the GFCI device. The connection
points labeled "WHITE" are the "NEUTRAL" return
conductor connections, and where the blue wires are
connected. These connections must also be connected
correctly with respect to the line and load side of the
GFCI device.
54
Chapter 8
high voltage connection points to
Line
will be the incoming