▣ ▣ MAGNETO
Using the pocket tester, measure the resistance
between the lead wires in the following table.
If the resistance is not within the specified value,
replace the stator coil, with a new one.
Stator coil resistance
Pick-up coil
Charging coil
Pocket Tester : 09900-25002
Tester knob indication : Resistance ( Ϊ Ϊ )
CAUTION
When mounting the stator on magneto cover,
apply a small quantity of THREAD LOCK "1324"
to the threaded parts of screws.
THREAD LOCK " " 1324" "
▣ ▣ MAGNETO NO-LOAD PERFORMANCE
Disconnect the three lead wires from the magneto
terminal.
Start the engine and keep it running at 5,000 rpm.
Using the pocket tester, measure the AC voltage
between the three lead wires.
If the voltage is under the specified value, replace the
magneto with a new one.
Standard NO-load per-
for-mance of magneto
Pocket tester : 09900-25002
Tester knob indication : Voltage (
Standard
G-L 80 ~ 120 Ϊ
Y-Y 0.7 ~ 1.3 Ϊ
Over 70 V (at 5,000 rpm)
)