Battery-filling with acid
(only
immed
iately
before delivery)
•
Only fill the
battery
with
acid
shortly before it is needed.
•
Unscrewthe
stoppers.
•
Fill the batterywith pure
accumulatorsulphuric acid (to
VDE
051
0, density: 1.28
kg/l,
at 20°C acid
temperature) upto
the
specified
level
(MAX mark).
•
Allow
the
batteryto
stand
for app. 1 hour
(the
chemical
reaction generates
heat.
Max.
temperature 40°C, otherwise
there
is a
risk
of short-circuiting between
the plates), then
shake gently or
tilt (to
expel air) and
top up
acid to the
.
correct
level
if
necessary.
•
Screw in
stoppers
loosely (only tighten once
the
battery has been
charged).
•
When
the dry,
pre-charged battery is first
filled with acid
,
it
will produce only app
.
60% of its rated output. Chargi ng is
therefore essential.
00
-
22.0
Battery
-
charging
Warning:
Max.
charging current must
not
exceed 10
%
o(
the
baffery
capacity.
Example:
25
Amp/h battery
=
max. 2.5
Amp
charging curren!.
Charging time
=
5 ..
.
10 hours
•
Battery charge can be determined by measuring the
acid
density.
•
Acid density when
battery
fully charged
=
1.26 ... 1.30
kg/l
at
20°C.
• Shake
the battery
gently after charging so that any gas
bubbles rise
to the
surface.
•
When the fluid has
settled again,
top up
battery acid to
MAX.
mark if necessary.
Screw the stopper
in firmly.
•
Connect
up breather line.
Brake fluid level:
The
brake
fluid
reservoirs atthe front
...
...
rear must befil led to
between
the
MIN
and MAX
marks only
1
• • • •
1
and K
75
s)
.
Brake fluid level must never
be
allowed to
fall
below the
MIN
mark, as
air may otherwise penetrate
into
the brake
system.
Only use quality
grade
DOT
4 brake
fluid if
topping
up
is
necessary.
8.87
Need help?