Cleaning Methods
Cleaning kits are provided in the Developer Kits, as well as being sold separately. These kits include
cotton swabs, several "wet wipe" tissues in foil pouches, a corona wire cleaning brush, and instructions.
Users and service personnel are encouraged to use them on the schedule shown below.
Users
Users should perform the following actions at the frequencies listed below:
When Refilling the Toner (approximately every 8,000 pages)
Replace the Waste Toner Container.
Replace the Fuser Felt Wiper.
Clean the Fuser Heat Roller.
Clean the Transfer Corona Wire.
Clean the Charge Corona Wire.
When Replacing the OPC Drum Unit (approximately every 30,000 pages)
Clean inside the printer as needed.
When Replacing the Developer Unit (approximately every 100,000 pages)
Replace the Ozone Filter.
Clean the Fuser Heat Roller.
Clean the Transfer Corona Wire.
Clean the Charge Corona Wire.
When Using Label Paper and Regular Paper alternately
Clean the Tension Roller (after each 4,000 pages of labels printed—see the information on
the next page).
WARNING:
1–4
Turn off power to the printer before cleaning it.
Chapter 1 – Introduction
Need help?
Do you have a question about the L1024 and is the answer not in the manual?