5
BRIDGE MODE SETTING SCREEN
7. [Bridge Connection] Menu (continued)
M About the SelCall Number Converting
When a SelCall number is shared beyond the site, you cannot call a radio across the site due to "SelCall number
duplication." The SelCall Number Convert function solves this problem by automatically converting the SelCall
number.
Here is an example to show how the function works.
The radio in area A (ID=1) is calling the radio in area B (ID=2) using a provisionally assigned SelCall number
(902).
The provisionally assigned SelCall number is converted into the actual one (902 to 2), according to the
number conversion table.
Thus they can talk each other across the sites.
Note: This is an example in the Conventional mode.
Area A
Repeater A
P 0
P 1
P 2
P 3
P 4
ID: 1
(Provisional number: 801)
• The conversion table for the above example. <Area A>
• The conversion table for the above example. <Area B>
[D-TRX1]
VE-PG3
(192.168.0.1
[LAN]
ID: 2
(Provisional number: 802)
[Bridge Connection]–[SelCall Number Converting]
Area B
IP
Network
[LAN]
(Provisional number: 901)
5-62
[D-TRX1]
VE-PG3
(192.168.0.3
Repeater B
P 0
P 1
P 2
P 3
P 4
ID: 1
ID: 2
(Provisional number: 902)
Need help?