2AV/X
Maintenance
item No.
U914
Switching between fax and copier modes
Description
Selects whether the fax or copier mode is given priority when the optional facsimile kit is installed to use the
copier as a fax.
Purpose
To select the mode that is used more frequently by the user.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select the priority mode (fax mode or copier mode) using the cursor up/down keys.
2. Press the start key. The screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
U917
Setting the reading/writing of backup data
1-4
Description
Selects whether to read out the backup data on the main PCB to the NVRAM on the memory tool PCB or to
write backup data on the NVRAM on the memory tool PCB to the main PCB.
When the memory is initialized (maintenance items U020, U021, U022 and U252), this is set to read out the
backup data from the main PCB to the NVRAM on the memory tool PCB. To write the backup data to the
main PCB from the NVRAM on the memory tool PCB, change the setting before starting writing.
Purpose
Used when replacing the main PCB.
Method
1. Press the start key. The screen for selecting an item is displayed.
2. Select READ or WRITE using the cursor up/down keys.
READ
WRITE
3. Press the start key.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key when operation
stops. The screen for selecting a maintenance item No. is displayed.
U990
Checking/clearing the time for the exposure lamp to light
Description
Displays, clears or changes the accumulated time for the exposure lamp to light.
Purpose
To check duration of use of the exposure lamp. Also to clear the accumulated time for the lamp after
replacement.
Method
Press the start key. The accumulated time of illumination for the exposure lamp is displayed in minutes.
Clearing
1. Select CLEAR using the cursor up/down keys.
2. Press the start key. The accumulated time is cleared, and the screen for selecting a maintenance item
No. is displayed.
Setting
1. Enter a six-digit accumulated time using the numeric keys.
2. Press the start key. The time is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the accumulated time, press the stop/clear key. The screen
for selecting a maintenance item No. is displayed.
1-4-50
Display
Reading out the backup data
Writing backup data
Description