Maintenance
item No.
U251
Checking/clearing the maintenance count
Description
Displays, clears and changes the maintenance count.
Purpose
To check the maintenance count. Also to clear the count during maintenance service.
Method
1. Press the start key.
2. Select the item by lighting a copy exposure indicator using the copy exposure adjustment keys.
Copy exposure indicator Description
Exp. 1
Exp. 2
Exp. 3
Clearing
1. Light exp. 3.
2. Press the start key. The count is cleared, and the indication for selecting a maintenance item No. appears.
Setting
1. Change the count using the numeric or zoom +/– keys.
2. Press the start key. The count is set, and the indication for selecting a maintenance item No. appears.
Completion
To exit this maintenance item without changing the count, press the stop/clear key. The indication for selecting
a maintenance item No. appears.
U252
Setting the destination
Description
Switches the operations and screens of the machine according to the destination.
Purpose
To be executed after replacing the backup RAM on the main PCB or initializing the backup RAM by running
maintenance item U020, in order to return the setting to the value before replacement or initialization.
Method
Press the start key.
Setting
1. Select the destination using the zoom +/– keys.
Display
JPn
Inc
EUP
ASA
2. Press the start key. The setting is set, and the machine automatically returns to the same status as when
the power is turned on.
Completion
To exit this maintenance item without changing the current count, press the stop/clear key. The indication for
selecting a maintenance item No. appears.
Supplement
The specified initial settings are provided according to the destinations in the maintenance items below. To
change the initial settings in those items, be sure to run maintenance item U021 after changing the destination.
• Initial setting according to the destinations
Maintenance
item No.
253
255
348
First 3 digits
Last 3 digits
Clearing the count
Description
Metric (Japan) specifications
Inch (North America) specifications
Metric (Europe) specifications
Metric (Asia Pacific) specifications
Title
Switching between double and
single counts
Setting auto clear time
Setting the copy density
adjustment range
Description
Setting range
000 to 999
000 to 999
— — —
Japan
Inch
Single
Double
120 s
90 s
Normal
Special area
2AV/X
Initial setting
000
000
— — —
Europe Metric,
Asia Pacific
Double
90 s
Special area
1-4-87
1-4

Hide quick links: