Kyocera Mita KM-1530 Service Manual page 71

Kyocera mita copier service manual
Hide thumbs Also See for KM-1530:
Table of Contents

Advertisement

2AV/X
Maintenance
item No.
U099
Checking the original size detection
Description
Displays the original width detection data and sets the original width detection threshold.
Purpose
To check the original width detection. Also to change the original size detection threshold if the size of the
original on the contact glass is detected incorrectly.
Start
1. Press the start key. The screen for selecting an item is displayed.
2. Select the item.
3. Press the start key. The screen for executing is displayed.
DATA
B/W LEVEL
Method to display the original width detection data
1. Place an original on the contact glass and turn the original detection switch on. The exposure lamp turns
1-4
on and the width of the original is detected. The scanner data taken at the nine points from (1) at the
machine rear to (9) at the machine front is displayed on the message display as follows.
The data is displayed within the range of 000 to 255, 000 indicating white (original present) and 255
indicating black (no original).
2. To return to the screen for selecting an item, press the stop/clear key.
Method to set or check the original size detection threshold
1. Place an original on the contact glass and turn the original detection switch on. The original size
detection starts and detection data is displayed.
LEVEL
WAIT TIME
ORIGINAL AREA
SIZE
B_DATA
W_DATA
* See Paper size in U073 for the paper size for each setting.
2. To change the original size detection threshold, select LEVEL or WAIT TIME using the cursor up/down
keys and change the setting using the cursor left/right keys.
3. Press the start key. The value is set.
4. To return to the screen for selecting an item, press the stop/clear key.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item
No. is displayed.
1-4-22
Display
Checking the original width detection data
Setting or checking the original width detection threshold
Display
Scanner data threshold
Time between original detection switch turning on
and reading-in of scanner data
Detected original width
Original size detected by scanner data and original
size sensor detection data
Black (no original) data at the point on the boundary
between original area and no original area
White (original present) data at the point on the
boundary between original area and no original area
Description
Description
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Figure 1-4-6
Description
Data
Initial
Remarks
range
setting
0 to 255
Adjustable
170
0 to 100 ms
Adjustable
50
0 to 350 mm
0 to 63*
0 to 255
0 to 255

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-2030

Table of Contents