Kyocera Mita KM-1530 Service Manual page 125

Kyocera mita copier service manual
Hide thumbs Also See for KM-1530:
Table of Contents

Advertisement

2AV/X
Maintenance
item No.
U100
Setting the surface potential
Description
Changes the surface potential by changing the grid control voltage. Also performs main charging.
Purpose
To set the surface potential or check main charging. Also used when reentering data after initializing the set
data.
Start
1. Press the start key. A selection item appears.
2. Select the item using the copy exposure adjustment keys.
Display (copy exposure indicator)
— — — (exp. 1)
on1 (exp. 2)
on2 (exp. 3)
Method for main charger output
1. Press the start key. The selected operation starts.
1-4
2. To stop operation, press the stop/clear key.
Setting the grid control voltage
1. Change the setting using the zoom +/– keys.
Description
Grid control voltage
Increasing the setting makes the surface potential higher, and decreasing it makes the potential lower.
Change in value per step: approximately 3.6 V
2. Press the start key. The value is set.
Interrupt copy mode
While this maintenance item is being performed, copying from an original can be made in interrupt copy mode.
Completion
Press the stop/clear key when main charger output stops while a selection item is displayed. The indication for
selecting a maintenance item No. appears.
1-4-76
Description
Description
Changing the grid control voltage
Turning the main charger on
Turning the main charger on and the laser scanner unit
on and off
Setting range
0 to 255
Initial setting
184