(1) Formation of magnetic brush

The developing roller consists of a magnet roller with five poles and a sleeve roller. Rotation of the sleeve roller around
the magnet roller entrains developer, which in turn forms a magnetic brush at pole N1 on the magnet roller. The height of
the magnetic brush is regulated by the doctor blade; the developing result is affected by the position of the poles on the
magnet roller and the position of the doctor blade.
A developing bias voltage generated by the high-voltage transformer PCB (HVTPCB) is applied to the developing roller
to provide image contrast.
A
A: Distance between the doctor blade and developing roller: 0.6±0.05 mm
Figure 2-1-14 Forming a magnetic brush
HVTPCB
CN1-9
CN1-6
DB
CN1-4
WTDSW
TFM
Figure 2-1-15 Developing section block diagram
1 Developing unit housing
2 Developing roller
3 Toner sensor (TNS)
4 Doctor blade
5 Right developing spiral
6 Left developing spiral
7 Developing paddle
MPCB
24 V DC
CN4-1
DB REM
CN4-4
DB CONT
CN4-7
CN13-7
TNS SIG
CN13-2
TNS CONT
CN13-3
CN11-1,2
2AV/X
2-1
2-1-11