2AV/X
Maintenance
item No.
U162
Stabilizing fixing forcibly
Description
Stops the stabilization fixing drive forcibly, regardless of fixing temperature.
Purpose
To forcibly stabilize the machine before the fixing section reaches stabilization temperature.
Method
1. Press the start key. The screen for executing is displayed.
2. Press the start key. The forced stabilization mode is entered, and stabilization operation stops regardless
of fixing temperature. The screen for selecting a maintenance item No. is displayed.
To exit the forced stabilization mode, turn the power off and on.
Completion
To exit this maintenance item without executing forced fixing stabilization, press the stop/clear key.
U163
Resetting the fixing problem data
Description
Resets the detection of a service call code indicating a problem in the fixing section.
1-4
Purpose
To prevent accidents due to an abnormally high fixing temperature.
Method
1. Press the start key. The screen for selecting an item is displayed.
2. Select EXECUTE using the cursor up/down keys.
3. Press the start key. The fixing problem data is initialized.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
U196
Turning the fixing heater on
Description
Turns the fixing heater on.
Purpose
To check fixing heater.
Method
1. Press the start key. The screen for executing is displayed.
2. Press the start key. The heater turns on for 3 s and then turns off.
Completion
Press the stop/clear key when fixing heater is off. The screen for selecting the maintenance item No. is
displayed.
U199
Checking the fixing temperature
Description
Displays the fixing temperature and the ambient temperature.
Purpose
To check the fixing temperature and the ambient temperature.
Method
Press the start key. The fixing temperature and ambient temperature are displayed in centigrade (°C).
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.