2AV/X

(3) Detaching and refitting the left registration cleaner assembly

Follow the procedure below to replace the left registration cleaner assembley.
Procedure
1. Open the bypass tray and paper conveying
unit.
2. Remove the transfer roller unit (see page 1-6-
47).
3. While rotating the left registration roller in the
direction of the arrow in the diagram, remove
the left registration cleaner assembly.
4. Replace the left registration cleaner assembly
and refit all the removed parts.

(4) Detaching and refitting the right registration cleaner assembly

Follow the procedure below to replace the right registration cleaner assembly.
Procedure
1-6
1. Open the bypass tray, paper conveying unit
and front cover and then remove the image
formation unit (see page 1-6-40).
2. Remove the right registration cleaner unit by
lifting its front first.
3. Replace the right registration cleaner unit and
refit all the removed parts.