Code
Contents
C620
Abnormally low fixing unit
thermistor temperature
• The fixing temperature remains below
100˚C/212˚F for 10 s during copying.
C630
Abnormally high fixing unit
thermistor temperature
• The fixing temperature exceeds
240˚C/464˚F for 10 s.
C710
Toner sensor problem
• The sensor output voltage is outside
the range of 0.5 to 4.5 V during toner
control.
• The toner sensor control voltage
cannot be set within the setting range
when maintenance item U130 is run.
C730
Broken external temperature
thermistor wire
• The input voltage is above 4.5 V.
Causes
Check procedures/corrective measures
Fixing heater
Check and reinstall if necessary.
installed
incorrectly.
Broken fixing
Check for continuity. If none, replace fixing
heater wire.
heater.
Poor contact in
Check the connection of connector CN12
the fixing unit
on the main PCB and the continuity across
thermistor
the connector terminals. Remedy or
connector
replace if necessary.
terminals.
Measure the resistance. If it is ∞ Ω, replace
Broken fixing unit
the fixing unit thermistor.
thermistor wire.
Fixing unit
Check and reinstall if necessary.
thermistor
installed
incorrectly.
Fixing unit
Check for continuity. If none, replace the
thermostat
fixing unit thermostat. Check the operation
triggered.
of the cooling fan and repair if necessary.
Measure the resistance. If it is 0 Ω, replace
Shorted fixing unit
thermistor.
the fixing unit thermistor.
Broken fixing
Replace the power source PCB.
heater control
circuit on the
power source
PCB.
Defective toner
Replace the toner sensor.
sensor.
Poor contact of
Reinsert the connector. Also check for
the toner sensor
continuity within the connector cable. If
connector
none, repair or replace the cable.
terminals.
Developer
Replace the developer.
problem.
Poor contact of
Reinsert the connector. Also check for
the humidity
continuity within the connector cable. If
sensor PCB
none, repair or replace the cable.
connector
terminals.
Defective external
Replace the humidity sensor PCB.
temperature
thermistor.
Remarks