4.1.20
Overview
Syntax
Parameter(s)
4
SERVIS IP-Serial
74
1p Converter
User's Guide
redirect Command
Configures redirect connection.
redirect [on | off] [com | ip xx.xx.xx.xx [-s | -c]]
None = Displays the current settings of the redirect
connection.
on = Establishes a redirect connection.
off = Disconnects the redirect connection.
com = Specifies the direct connection of the target port
ip xx.xx.xx.xx = The destination IP address when
-s = The server setting when establishing direct
-c = The client setting when establishing direct
Password required?
Notes
(1) If nothing either -s or -c is specified, then this defaults to the client
setting. Also, the IP address must be specified when specifying this.
(2) If the parameter is "on" and no following arguments are specified, the
settings will default to the settings of the /etc/rc.conf and
/etc/portmng.cf files.
(3) If the parameter is "on" and following arguments are specified, settings
are based on those arguments.
(4) If the parameter is "off", then following arguments cannot be specified.
(5) First ensure that the serial port settings of the client device and server
device match when establishing a dual connection.
Example (from the local console)
With an Ethernet connection, executing the following command enables
the COM direct connection.
$ redirect on com
Enter
$
and local console port.
establishing direct connections between two target
ports.
connections between two target ports.
connections between two target ports.
No