Port Command - Fujitsu FX-3001SR User Manual

Servis ip-serial 1p converter
Table of Contents

Advertisement

4.1.17
Overview
Syntax
4
Parameter(s)
Password required?
SERVIS IP-Serial
70
1p Converter
User's Guide

port Command

Sets the target port or local console port (when the
terminal emulator is running).
The port settings are saved to the port file.
port [-t | -l] [speed] [bit] [parity] [stop] [flow] [xon] [xoff]
port [-r1 | -r2 | rw] [port-no]
port [-n]
-t = Sets the target port
-l = Sets the local console port when the terminal
emulator is running
speed = Sets the baud rate
bit = Bit length 7 - 8
parity = Parity bit (0 = none, 1 = odd, 2 = even)
stop = Stop bit (1 or 2)
flow = Flow control (n = none, h = hardware flow, x =
xon/xoff flow)
xon = xon character code 0x?? (hexadecimal setting)
xoff = xoff character code 0x?? (hexadecimal setting)
-r1, -r2 = Sets the read-only port number
-wo = Sets the write-only port number
-rw = Sets the read/write port number
port-no = Port number
-n = Displays the currently set TCP port number and the
current connecting status
(o: connecting, -: unconnection)
Notes
(1) If the target port is connected by the terminal emulator or direct
connection, port changes cannot be performed using the port
command.
(2) If flow control is set to n or h, an error occurs when entering xon or xoff.
(3) Specify the port number within the range of 5000 - 65535.
300, 1200, 1800, 2400, 4800, 9600, 14400, 19200,
28800, 38400, 57600, 115200
No

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx-3001srf

Table of Contents