Fujitsu FX-3001SR User Manual page 170

Servis ip-serial 1p converter
Table of Contents

Advertisement

Error
Message
code
0017
System program CF not ready 0xXXXX
Error Code 0017
0018
File system CF not ready 0xXXXX
Error Code 0018
7
0019
System program read error XXX
Error Code 0019
SERVIS IP-Serial
160
1p Converter
User's Guide
Detail
When booting from the CF card, the system program
could not be read because of an error with the CF
card.
The displayed number is the error status
(hexadecimal).
0xFFFF is an operational time out.
For numbers other than 0xFFFF, the error is shown
by bit.
0x0080: Bad block or CRC error
0x0040: Unrecoverable error (data ECC error)
0x0010: Sector error or missing error for specified
sector ID
0x0004: Command was aborted (CF card is not
ready, write error, or invalid command)
0x0001: General error
Solution:
Contact our technical support.
When booting from the CF card, the file system could
not be read because of an error with the CF card.
The displayed number is the error status
(hexadecimal).
0xFFFF is an operational time out.
For numbers other than 0xFFFF, the error is shown
by bit.
0x0080: Bad block or CRC error
0x0040: Unrecoverable error (data ECC error)
0x0010: Sector error or missing error for specified
sector ID
0x0004: Command was aborted (CF card is not
ready, write error, or invalid command)
0x0001: General error
Solution:
Contact our technical support.
When booting from the CF card, the system program
could not be read.
File information may be broken.
The displayed number is the error number (decimal).
27: File too large
Solution:
Check that a bootable CF card is inserted.
Reinsert the CF card in the slot and press the
RESET button or turn the power off and then back
on.
If that does not work, contact our technical support.