Align cartridges

For best results, perform a calibration each time you install a new cartridge.

Paper axis calibration

External factors such as room temperature, storage temperature, and humidity
can have a deforming effect on media. A paper axis calibration corrects for
minor paper length fluctuations, which you carry out using a precision ruler of
at least 34 (850 mm) inches long.
M M M M
To print the paper axis test
Load the media that you want to use. Check that the length is at least 36 (91
1
cm) inches long.
Press
2
Utility/Calibration/Paper Axis Test
Remove the media from the printer and measure the distance between the
3
witness marks. The distance between the marks should be exactly 838.2 mm
(33.00 ").
If the distance between the marks is different from that shown on the display,
4
press
Paper Axis
Press
I

Define calibration units

You can set the calibration units to English or Metric.
M M M M
To set calibration units
Select
1
Setup/User Setup/Units Select
Choose
2
Getting started
to enter the value of the distance you have just measured.
.
OK
or
.
English
Metric
. The printer prints two marks.
.