Oce CS 5090 User Manual page 130

Table of Contents

Advertisement

Various nozzles are clogged or stop firing
Repeat prime several times.
I
Remove, clean, and re-install cartridge; repeat prime. Do not use alcohol on
I
the jet area.
Clean service station; clean cartridge again; repeat prime.
I
Clean cartridge electrical contacts using a cotton swab moistened with water.
I
Dry contact. Repeat prime. Do not use acetone or any other harsh cleaner as
this may cause damage to the flex cable.
Nozzle may have failed. Replace cartridge. Check for nozzle clogs by using
I
the suction bulb on the cartridge nozzle plate.
Check to see whether spray from printing has contaminated the flex contact.
I
Remove the cartridge and wipe the carrier flex and cartridge flex with a
cotton swab dipped in alcohol.
Run prime. If sections of the print are missing, replace the cartridge.
I
Ink spills on the flex cable
Clean the flex cable gently with a cotton swab moistened with water. Do not
I
use acetone or any other harsh cleaner as this may cause damage to the flex
cable.
Printer settings are lost when printer is turned off or rebooted
Be sure to save your printer settings to a User number (see 'To save
I
user-defined settings' on page 50). When you are ready to print, select the
User number with the settings that you saved.