Within the printed test pattern, each jet is represented by a short horizontal
I
line. Together, these short horizontal lines form a "stair step" pattern.
Electrically defective jets appear as solid bars for which you can compensate.
I
Clogged jets appear as gaps or misdirected lines in the "stair step" pattern,
I
which you clear manually.
The print modes for which compensation is available are shown above the
I
test pattern.
In the above example, the prime test shows that there are three electrically
I
defective jets and one clogged jet. The header indicates that you can
compensate for the electrically defective jets in the 4-pass mode. But you
must clear the clogged jet manually. See 'Clear clogged jets' on page 122 for
further information.
If all jets appear to be defective, reinstall the cartridges.