Prime Ink Delivery Line
To prime the ink delivery line, open the valve cover.
Attach the cartridge tubing needle to the appropriate
valve. Press the septum fitting onto the needle securely.
Snap the valve cover closed.
Using the ink prime device located in the ink prime holster
insert the cartridge tubing needle end into the suction tip
of the ink prime 1 cm or approximately ½".
Prime the ink delivery line with a steady burst by depress-
ing and holding the ink prime activation button.
When ink floods the ink delivery line, release the activation
button and disconnect the needle from the ink prime and
insert into the cartridge.
Twist the black cartridge tubing needle clockwise tightly to
secure onto the cartridge. Repeat process for the other ink
lines.