Unique Switches Adjustment - Muratec MFX-2500 Field Engineering Manual

Hide thumbs Also See for MFX-2500:
Table of Contents

Advertisement

Options

6.8.3.2 Unique Switches Adjustment

Setting the Unique Switches
If necessary, you must set the following switches.
1. From Fax standby mode, press MENU, *, 4.
2. Select the desired memory switch by pressing a one-touch key plus a number on the keypad.
3. Press [Enter].
Unique Switch d:0 – Modem
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
1
3429 baud symbol rate when
communicating at V.34
0: No
1: Yes
4
1
3200 baud symbol rate when
communicating at V.34
0: No
1: Yes
3
1
3000 baud symbol rate when
communicating at V.34
0: No
1: Yes
2
1
2800 baud symbol rate when
communicating at V.34
0: No
1: Yes
1
0
Factory use only
0
1
2400 baud symbol rate when
communicating at V.34
0: No
1: Yes
Unique Switch d:1 – Modem
Initial
Switch
Setting
7
0
6
0
5
0
Forced 2400 symbol rate
4
0
when probing SNR is
3
1
adverse
2
1
1
1
0
1
Adjust
If the error frame often occurs because of the
symbol rate is too high, setting this switch to "1"
mask that symbol rate and keep down the
occurrence of error frame.
If the error frame often occurs because of the
symbol rate is too high, setting this switch to "1"
mask that symbol rate and keep down the
occurrence of error frame.
Adjust
SNR means that Signal Noise Ratio. If the SNR is
less than the threshold you set, the data pump
overrides the bandwidth evaluation algorithm and
forced the symbol rate to 2400 baud.
6-94
Second phone line
Usage/Comments
Usage/Comments

Advertisement