Paper Feed Unit

6.4.2 DIS/REASSEMBLE, ADJUSTMENT

6.4.2.1 Disassembly

6.4.2.1.1 Removal of the Paper Take-Up Rolls
Lock point
6.4.2.1.2 Cleaning of the Paper Take-Up Rolls
6.4.2.1.3 Cleaning of the Vertical Transport Roller/Rolls
1. Remove the upper cassette.
2. Unlock the Paper Take-Up Roll and slide it off its shaft.
Note: When installing the roll, make sure it securely locks into
place as illustrated.
Wipe the surface of the Paper Take-Up Rolls clean with a soft cloth
dampened with alcohol.
Wipe the surface of the Vertical Transport Roller/Rolls clean with
a soft cloth dampened with alcohol.